<strong>SonTek</strong>/<strong>YSI</strong><br />

114<br />

Maximum Range for MinVal and MaxVal Parameters<br />

OutParam<br />

VELX<br />

MinVal<br />

-1000<br />

MaxVal<br />

1000<br />

Units*<br />

cm/s<br />

VELY<br />

-20<br />

-1000<br />

20<br />

1000<br />

ft/s<br />

cm/s<br />

VELMAG<br />

-20<br />

-1000<br />

20<br />

1000<br />

ft/s<br />

cm/s<br />

AVGAMP<br />

TEMP<br />

-20<br />

0<br />

-5<br />

20<br />

255<br />

45<br />

ft/s<br />

counts<br />

°C<br />

PRESS<br />

20<br />

0<br />

113<br />

50<br />

°F<br />

dbar<br />

LEVEL<br />

0<br />

0<br />

150<br />

50<br />

psi<br />

m<br />

0<br />

150<br />

ft<br />

FLOW<br />

CELLEND<br />

Not implemented<br />

1<br />

Not implemented<br />

22<br />

N/A<br />

m<br />

1<br />

72<br />

ft<br />

*Caution: Unit value depends on the Output Format (OF command) in effect when the AO was configured. If OF is changed<br />

after the AO setup, all channels are reset and must be re-entered. Ensure you set OF before setting up the AO channels.<br />

• Examples of command syntax:<br />

SAO<br />

Returns AO settings for all <strong>Argonaut</strong> channels (1 through 8) in a column format. Example:<br />

Chan Parameter MinVal MaxVal Unit(*see above Caution)<br />

1 VelMag 0 20 ft/s<br />

2 VelX -4 4 ft/s<br />

3 VelY -4 4 ft/s<br />

4 Level 0 10 ft<br />

5 AvgAmp 0 128 counts<br />

6 Press 0 5 psi<br />

7 Temp 20 40 °F<br />

8 CellEnd 2 10 ft<br />

SAO Chan OutParam MinVal MaxVal<br />

Configures the selected channel (Chan) of the <strong>Argonaut</strong> to send OutParam to the<br />

Converter’s address (Chan) with the specified minimum and maximum values. The<br />

following example tells <strong>Argonaut</strong> channel 3 to send the Y-velocity component to the<br />

Converter whose address is 3 and to limit the scaling range to ±400 cm/s (or ft/s).<br />

SAO 3 VelY –400 400<br />

SAO Chan RESET<br />

Clears the selected channel. The following example would clear all entries made for<br />

channel 3 of the <strong>Argonaut</strong>.<br />

SAO 3 RESET<br />

<strong>Argonaut</strong> Operation <strong>Manual</strong> Firmware Version 7.9 (May 1, 2001)