<strong>SonTek</strong>/<strong>YSI</strong><br />

To install a new battery pack, use the following steps.<br />

1. Inspect the o-rings and surfaces on both the end cap and housing; replace the o-rings if<br />

necessary.<br />

2. Place the new battery pack into the housing with the cables coming from the top.<br />

3. Feed the battery cable through a hole in the internal retaining plate.<br />

4. Place the internal retaining plate on top of the battery pack, and secure with the screws.<br />

5. Connect the battery pack cable to the end cap. The connector is keyed and can only be<br />

aligned in one direction.<br />

6. Install the end cap onto the battery housing; the alignment of the end cap relative to the<br />

housing is not important. Tighten the screws sufficiently to place the end cap flush against<br />

the housing; do not over-torque as this can damage the threaded inserts in the housing.<br />