3.10. SDI-12 Interface Commands<br />

Starting with firmware version 7.5, the <strong>Argonaut</strong>-<strong>XR</strong> and SL offers internal SDI-12 (Serial-<br />

Digital Interface) capabilities that require no external devices or converters. Appendix 2<br />

describes the internal SDI-12 interface support in detail. The <strong>Argonaut</strong> commands are described<br />

in this section, and the format of the SDI-12 commands is described in Appendix 2.<br />

sdi12 ON<br />

• Places an <strong>Argonaut</strong>-<strong>XR</strong> or SL system in the SDI-12 interface mode.<br />

• To exit the SDI-12 interface mode, you must use the ?EXIT! command described below.<br />

sdi12address [d]<br />

• Default parameter: 1<br />

• Parameter range: 0 through 9<br />

• Without parameter: returns either the current SDI-12 interface address (if the SDI-12<br />

interface option is installed), or an error message (if the SDI-12 option is not installed).<br />

• When used with a valid integer parameter, sets the <strong>Argonaut</strong>’s SDI-12 interface address.<br />

• If more than one sensor is to be connected to the SDI-12 bus, make certain each sensor has<br />

a unique address.<br />

sdi12format [SIDEKICK|SONTEK]<br />

• When given without parameter, returns the current data output format being used.<br />

• When given with a valid parameter, sets the data output format. Appendix 2 describes<br />

these two formats in detail.<br />

?EXIT!<br />

• Executing this command causes the <strong>Argonaut</strong> to exit the SDI-12 interface mode and return<br />

to the standard <strong>Argonaut</strong> operating mode.<br />

24<br />

<strong>Argonaut</strong> Operation <strong>Manual</strong> Firmware Version 7.9 (May 1, 2001)