Receptor Easting (m) Northing (m) Elevation (m<br />

AOD)<br />

214<br />

Approximate<br />

Distance to<br />

Nearest Turbine<br />

(m)<br />

Hardwick (H8) 448166 386415 112 890<br />

9.21 The background noise survey was undertaken over the period 9th May<br />

2008 to 3rd July 2008. The sound level meters were set to log the LA90 and<br />

LAeq noise levels over the required ten minute intervals continuously over<br />

the deployment period.<br />

9.22 Simultaneous wind speed and direction measurements were measured<br />

using anemometry equipment located at 10 metres and 38m height<br />

respectively on a 60m mast located within the proposed wind farm site. A<br />

rain gauge was also installed at H5 to monitor rainfall over the duration of<br />

the noise monitoring survey.<br />

9.23 Wind speed/direction data and rainfall data were collected over the same<br />

time-scale, and averaged over the same ten minute periods as the noise<br />

data to provide the analysis of the measured background noise as a<br />

function of wind speed and direction. The clocks on the sound level meters<br />

were set to the BT Talking Clock (British Summer Time (BST)) and the<br />

anemometry mast was set up to Greenwich Mean Time (GMT). The data<br />

from the anemometry mast data was converted to BST (GMT+1hr) to<br />

correspond with the noise data monitoring periods.<br />

9.24 The noise meters were calibrated on deployment. Calibration and battery<br />

changes took place at approximately weekly intervals. No drifts greater<br />

than 0.2 dB(A) in calibration were found to have occurred on any of the<br />

noise meters. This is within the normal tolerances <strong>for</strong> such measurements.<br />

9.25 Table 9.2 provides a summary of the range of background noise levels<br />

measured during the monitoring period. Background noise levels during<br />

periods of rainfall have been excluded from this data in order to provide an<br />

accurate account of the background noise levels.<br />

Table 9.2 Summary of Background Noise Levels (dB(A))<br />

Receptor Quiet Daytime LA90, 10 min Night-time LA90, 10 min<br />

Morthen (H1) 29.2 – 61.2 29.2 – 58.1<br />

Brampton-en-lemorthen<br />

(H2)<br />

28.0 – 67.6 24.9 – 57.1<br />

Thurcroft (H3) 26.1 – 58.2 22.3 - 57.3<br />

Ulley (H4) 31.7 – 62.5 26.4 – 56.3<br />

Penny Hill (H5) 45.2 – 63.5 37.2 – 58.8<br />

Penny Hill Wind Farm<br />

Environmental Statement