Morthen (H1)<br />

Brampton-en-le-morthen<br />

(H2)<br />

Thurcroft (H3)<br />

Ulley (H4)<br />

9.29 Tables 9.3 and 9.4 detail the prevailing background noise, relevant criteria<br />

and predicted wind turbine noise levels <strong>for</strong> amenity hours and night-time<br />

operation. The tables also show the exceedance level which is the level of<br />

turbine noise relative to the noise criteria. A negative exceedance level<br />

indicates satisfaction of the noise criteria. Due to the lack of noise data<br />

during the night time at wind speeds >10.6ms-1, the background noise<br />

levels and hence noise exceedance levels could not be calculated and are<br />

left blank in Table 9.4. It is reasonable to assume that background noise<br />

levels will not decrease at windspeeds >10.6ms-1, there<strong>for</strong>e if turbine<br />

noise meets the noise limits at 10.6ms-1 (which it does at all receptors)<br />

there is a low likelihood of exceedance at windspeeds between 10.6 and<br />

12ms-1.<br />

Table 9.3 Exceedances of the ETSU-R-97 Derived Quiet Daytime Criterion<br />

Curves by the Predicted LA90 Wind Farm Noise Immission Levels at each of the<br />

Noise Assessment Locations<br />

Location<br />

216<br />

Wind Speed<br />

3 4 5 6 7 8 9 10 11 12<br />

Prevailing Background Noise Level: Amenity Hours 46.5 47.8 49.1 50.4 51.7 53.0 54.3 55.6 56.9 58.2<br />

Lower Noise Criterion : ETSU-R-97 51.5 52.8 54.1 55.4 56.7 58.0 59.3 60.6 61.9 63.2<br />

Upper Noise Criterion : ETSU-R-97 51.5 52.8 54.1 55.4 56.7 58.0 59.3 60.6 61.9 63.2<br />

Predicted Wind Turbine Noise LA90 - - 36.1 39.9 40.7 40.8 40.8 40.8 40.8 40.8<br />

Exceedance Level LA90 - - -18.0 -15.5 -16.0 -17.2 -18.5 -19.8 -21.1 -22.4<br />

Prevailing Background Noise Level: Amenity Hours 43.3 45.1 46.7 48.2 49.6 50.9 52.1 53.2 54.1 55.0<br />

Lower Noise Criterion : ETSU-R-97 48.3 50.1 51.7 53.2 54.6 55.9 57.1 58.2 59.1 60.0<br />

Upper Noise Criterion : ETSU-R-97 48.3 50.1 51.7 53.2 54.6 55.9 57.1 58.2 59.1 60.0<br />

Predicted Wind Turbine Noise LA90 - - 38.0 41.8 42.6 42.7 42.7 42.7 42.7 42.7<br />

Exceedance Level LA90 - - -13.6 -11.4 -12.0 -13.2 -14.3 -15.4 -16.4 -17.2<br />

Prevailing Background Noise Level: Amenity Hours 42.8 44.2 45.7 47.3 49.0 50.6 52.1 53.4 54.5 55.3<br />

Lower Noise Criterion : ETSU-R-97 47.8 49.2 50.7 52.3 54.0 55.6 57.1 58.4 59.5 60.3<br />

Upper Noise Criterion : ETSU-R-97 47.8 49.2 50.7 52.3 54.0 55.6 57.1 58.4 59.5 60.3<br />

Predicted Wind Turbine Noise LA90 - - 33.1 36.9 37.7 37.8 37.8 37.8 37.8 37.8<br />

Exceedance Level LA90 - - -17.6 -15.4 -16.3 -17.8 -19.3 -20.6 -21.7 -22.5<br />

Prevailing Background Noise Level: Amenity Hours 42.2 43.3 44.3 45.3 46.3 47.2 48.2 49.1 50.1 51.2<br />

Lower Noise Criterion : ETSU-R-97 47.2 48.3 49.3 50.3 51.3 52.2 53.2 54.1 55.1 56.2<br />

Upper Noise Criterion : ETSU-R-97 47.2 48.3 49.3 50.3 51.3 52.2 53.2 54.1 55.1 56.2<br />

Predicted Wind Turbine Noise LA90 - - 40.7 44.5 45.3 45.4 45.4 45.4 45.4 45.4<br />

Exceedance Level LA90 - - -8.6 -5.8 -6.0 -6.8 -7.8 -8.7 -9.7 -10.8<br />