DSKCHR [CALLI 45]<br />

5 . DCUCH<br />

The size characteristics are:<br />

Bits Symbol Meaning:<br />

0-8 DC.UCC Number of blocks per cluster.<br />

9-17 DC.UCT Number of blocks per track.<br />

18-35 DC.UCY Number of blocks per cylinder.<br />

6 .DCUSZ<br />

7 .DCSMT<br />

<strong>10</strong> .DCWPS<br />

11 . DCSPU<br />

12 . DCK4S<br />

13 .DCSAJ<br />

Number of 128-word blocks on the unit.<br />

Mount count for the structure. This count 1S the<br />

number of jobs that performed a MOUNT command for<br />

this file structure without executing a DISMOUNT<br />

command. Note that LOGIN performs an implied<br />

MOUNT of all structures in DSK, the default job<br />

search list.<br />

Number of words per SAT block.<br />

Number of SAT blocks for each unit .<br />

Space (in K) allocated for swapping .<br />

Mount word for the structure:<br />

Value<br />

Meaning<br />

0, , 0 No job or more than one job has the<br />

structure mounted.<br />

-1, ,n One job (number n) has the structure<br />

mounted and the structure is not<br />

single-access.<br />

0, ,n One job (number n) has the structure<br />

mounted and -the structure is<br />

single-access.<br />

14 . DCULN<br />

15 . DCUPN<br />

16 .DCUID<br />

17 .DCUFS<br />

SIXBIT logical name of the unit .<br />

SIXBIT physical name of the unit.<br />

SIXBIT identification of the unit.<br />

First logical block to be used for swapping.<br />

20 . DCBUM<br />

21 . DCCYL<br />

Number of blocks per unit<br />

cylinders) .<br />

Current cylinder number.<br />

(including maintenance<br />

22 . DCBUC<br />

23 .DCLPQ<br />

24 . DCLTQ<br />

25 . DCALT<br />

26 . DCOWN<br />

Number of blocks per unit in PDP-II<br />

mode.<br />

Length of the position wait queue.<br />

Length of the transfer wait queue.<br />

Unit name for alternate port.<br />

Owner PPN of structure .<br />

compatibility<br />

27 . DCPAS<br />

Position in active swapping list if argument was a<br />

physical unit; -1 if not in list.<br />

22-94