24.12.2013 Views

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LATOP. [CALLI 221]<br />

22.80 LATOP. [CALLI 221]<br />

FUNCTION<br />

Performs Local Area Terminal (LAT)<br />

intended for customer use.<br />

CALLING SEQUENCE<br />

functions.<br />

This function is not<br />

addr:<br />

MOVE I ac,addr<br />

LATOP. ac,<br />

error return<br />

skip return<br />

EXP length<br />

function-code<br />

argument list<br />

In the calling sequence,<br />

information:<br />

the program<br />

supplies<br />

the<br />

following<br />

o<br />

addr is the address of the argument list.<br />

o length is the total length of the argument list including<br />

this word<br />

o<br />

function-code is one of the following codes or symbols:<br />

Function Code<br />

Symbol<br />

Meaning<br />

o<br />

.LASET Sets a LAT parameter.<br />

1 .LACLR Clears a LAT parameter.<br />

2 . LASCH Shows LAT characteristics.<br />

3 .LASTC Shows terminal connects.<br />

4 .LASAS Shows adjacent servers.<br />

5 . LASCO Shows LAT counters.<br />

6 .LAZCO Clears LAT counters.<br />

7 . LARHC Requests host-initiated connect.<br />

<strong>10</strong> .LATHC Terminates a host-initiated connect.<br />

11 .LASHC Shows information about host-initiated<br />

connects.<br />

The argument list is different for each function code.<br />

arguments are desribed for each function code in<br />

sections.<br />

Therefore, the<br />

the following<br />

22.80.1 FUNCTION 0 (.LASET)<br />

Sets LAT parameters for the local node. The parameters you set using<br />

this function are dynamic parameters stored only in the host software.<br />

Your program must have JACCT or [1,2] privileges to set LAT<br />

parameters.<br />

The parameters you can set with .LASET are:<br />

Code<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Symbol<br />

. LPMAC<br />

. LPMCO<br />

. LPNUM<br />

. LPLAS<br />

. LPRLI<br />

Meaning<br />

Maximum number of active circuits.<br />

Maximum number of simultaneous connections.<br />

Host number .<br />

LAT access state.<br />

Circuit retransmit limit.<br />

22-204