LATOP. [CALLI 221]<br />

22.80.3 FUNCTION 2 (. LASCH)<br />

SholN's the LAT characteristics. The monitor returns a Show Buffer<br />

containing the values of both permanent and dynamic parameters.<br />

The argument block for this function is:<br />

Word<br />

o<br />

1<br />

2<br />

3<br />

Symbol<br />

.L<strong>AA</strong>CT<br />

.LAFCN<br />

.LABCT<br />

.LABFA<br />

Contents<br />

EXP<br />

EXP<br />

EXP<br />

EXP<br />

len<br />

. LASCH<br />

buffer-length<br />

buffer-addr<br />

Where len is the length of the argument block. Specify the number of<br />

words reserved for the Show Buffer in .LABCT, and the location of the<br />

ShOlN' Buffer in . LABFA.<br />

The Show Buffer is returned at the location you specified, and the<br />

contents of .LABCT are adjusted by the monitor to reflect the actual<br />

number of words used.<br />

The Show Buffer is formatted as shown below.<br />

Tab:le 22-3: LATOP. Show Buffer Format<br />

0------------------------17 18----------------------------35<br />

+--.--------------------~-------------------------------------+<br />

1 Maximum alloc. circuits 1 Number of alloc. circuits<br />

1--·----------------------------------------------------------<br />

1 Maximum active circuits 1 Number of active circuits<br />

1------------------------------------------------------------<br />

\ Mamimum connects \ Number of connects<br />

Host-number<br />

LAT terminal access status<br />

Host retransmit limit<br />

Host-multicast timer<br />

Host-circuit timer<br />

Reserved<br />

High-protocol version \ Low-protocol version<br />

------------------------------------------------------------\<br />

Protocol ECO \ Current-protocol version<br />

Maximum slot size<br />

Frame size<br />

Maximum slots<br />

Maximum services<br />

Host group codes (8 words)<br />

Host-name count<br />

Host-id count<br />

Host name (2 words)<br />

Host-id (13 words)<br />

Service Blocks (19 words per service, described below)<br />

+-_._---------------------------------------------------------+<br />