STRUUO [CALLI 50]<br />

22.164 STRUUO [CALLI 50]<br />

FUNCTION<br />

Modifies the search list for a job or for the system. Except for<br />

function 0, the functions and calling sequence for the STRUUO monitor<br />

call are subject to change; therefore you should not use anything but<br />

function 0 in user programs. Most functions require privileges.<br />

CALLING SEQUENCE<br />

MOVE ac, [XWD len,addr]<br />

STRUUO ac,<br />

error return<br />

skip return<br />

addr:<br />

fcncode<br />

first argument<br />

last argument<br />

In the calling sequence, the program supplies the following variables:<br />

o<br />

o<br />

len is the length of the argument list.<br />

addr is the address of the argument list. The format of the<br />

argument block is different depending on the function code<br />

specified in the first word of the argument block.<br />

o fcncode is one of the function codes described in the<br />

following subsections. The words up through last argument<br />

are arguments for the given function.<br />

The functions for STRUUO are:<br />

o .FSSRC Defines a new job search list.<br />

privileges.<br />

Never<br />

requires<br />

The format of the argument block is shown below:<br />

Word<br />

o<br />

1<br />

Symbol<br />

.FSFCN<br />

.FSCSO<br />

Contents<br />

The function code (.FSSRC)<br />

Offset to first word of file<br />

structure block, as used for<br />

argument list to JOBSTR monitor<br />

call.<br />

The first word of the argument block is followed<br />

by blocks of three words each. Each three-word<br />

block contains, in the first word, the structure<br />

name; in the second word, zero; and in the third<br />

word, flags that are described for the JOBSTR<br />

monitor call.<br />

22-409