24.12.2013 Views

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IPCFR. [CALLI 142]<br />

6 IPCDU%<br />

7 IPCDD%<br />

<strong>10</strong> IPCRS%<br />

11 IPCRR%<br />

12 IPCRY%<br />

13 IPCUP%<br />

14 IPCIS%<br />

15 IPCPI%<br />

16 IPCUF%<br />

17 IPCBJ%<br />

20 IPCPF%<br />

21 IPCPR%<br />

22 IPCIE%<br />

23 IPCBI%<br />

24 IPCUI%<br />

25 IPCRU%<br />

26 IPCRP%<br />

27 IPCRV%<br />

70 IPCFU%<br />

71 IPCCF%<br />

72 IPCFF%<br />

73 IPCQP%<br />

74 IPCBP%<br />

75 IPCDN%<br />

76 IPCNN%<br />

77 IPCBN%<br />

Receiver's PID unknown.<br />

Receiver disabled.<br />

No room in sender's quota.<br />

No room in receiver's quota.<br />

No room in system storage.<br />

Unknown page (send) or duplicate page (receive).<br />

Invalid sender PID.<br />

Not enough privileges.<br />

Unknown function code.<br />

Illegal job number.<br />

PID table full.<br />

Page requested, normal text.<br />

Paging I/O error.<br />

Bad index for system PID table.<br />

Undefined PID in system table.<br />

Receiver PID unknown or does not match job.<br />

Insufficient physical memory space available.<br />

Insufficient virtual memory space available to<br />

receive page.<br />

[SYSTEM] INFO has unknown internal error.<br />

[SYSTEM]IPCC request from [SYSTEM] INFO failed.<br />

[SYSTEM]INFO failed to complete an ASSIGN.<br />

PID quota exceeded.<br />

Unknown PID.<br />

Duplicate name.<br />

No such name.<br />

Name has illegal characters.<br />

EXAMPLES<br />

An example of the IPCFR.<br />

monitor call is shown below.<br />

PHB:<br />

PMB1:<br />

MOVE T2, [XWD 6,PHB]<br />

IPCFR. T2,<br />

JRST ERR<br />

JRST NORM<br />

EXP 0<br />

EXP 0<br />

EXP 0<br />

<strong>10</strong>"PMB1<br />

EXP 0<br />

EXP 0<br />

EXP 0<br />

EXP 0<br />

EXP 0<br />

;Length and address of packet<br />

; To be retrieved.<br />

;No flags.<br />

;Sender's PID<br />

;Receiver's PID<br />

;Length and address of packet<br />

;Message block to be retrieved<br />

;PPN of sender<br />

;Capabilities of sender<br />

EXP 0<br />

On a skip return from the IPCFR. monitor call, the packet has been<br />

retrieved from the input queue.<br />

Below is an example of what a response from [SYSTEM]INFO could be<br />

after a request for a PID.<br />

PHB<br />

PHB+1<br />

PHB+2<br />

PHB+3<br />

PHB+4<br />

PHB+5<br />

20<br />

2001<br />

31<br />

4"PMB1<br />

1, , 2<br />

260000,,<strong>10</strong>14<br />

;The packet was sent by [SYSTEM]INFO<br />

; [SYSTEM] INFO's PID<br />

;Job number of receiver<br />

;Length and address of packet message block<br />

;PPN of sender<br />

;Capabilities of sender<br />

22-190

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!