PIBLK. [CALLI 212]<br />

22.122 PIBLK. [CALLI 212]<br />

FUNCTION<br />

Returns the address of the 4-word interrupt control block for the<br />

current interrupt in progress on the Programmable Software Interrupt<br />

(PSI) system. Refer to Chapter 6 for more information about using the<br />

(PSI) system.<br />

This call is used by generic interrupt processes that service multiple<br />

interrupt conditions. Note that this call will not generate an<br />

interrupt when UUO interrupts are enabled.<br />

CALLING SEQUENCE<br />

SKIP RETURN<br />

PIBLK. ac,<br />

error return<br />

skip return<br />

On a successful return from this call, the address<br />

control block is stored in the ac.<br />

of the interrupt<br />

ERROR RETURN<br />

The call can take the error return with one<br />

codes stored in the ac:<br />

of the following error<br />

Code<br />

o<br />

1<br />

RELATED<br />

0<br />

0<br />

0<br />

0<br />

0<br />

0<br />

0<br />

0<br />

Symbol<br />

PSNIN%<br />

PSNIP%<br />

CALLS<br />

DEBRK.<br />

PIFLG.<br />

PIINI.<br />

PIJBI.<br />

PIRST.<br />

PISAV.<br />

PISYS.<br />

PITMR.<br />

Error<br />

The PSI system has not been initialized for this<br />

job.<br />

No interrupt is in progress.<br />

22-307