GETTAB TABLES<br />

.GTCVL -<br />

Current Virtual and Physical Limits<br />

GETTAB Table <strong>10</strong>2<br />

CONTENTS<br />

One word for each job running on the system, giving the current<br />

virtual and physical page limits for the job.<br />

INDEXED BY<br />

PDB word.<br />

<strong>Monitor</strong> Table:<br />

.PDCVL<br />

CALLING SEQUENCE<br />

MOVE ac, [XWD jobno, .GTCVL]<br />

GETTAB ac,<br />

error return<br />

normal return<br />

In the calling sequence, jobno is the number of a logged-in job.<br />

-1 for the current job.<br />

1=======================================================1<br />

1 Current virtual limit 1 Current physical limit 1<br />

1=======================================================1<br />

Use<br />