MTWAT. [MTAPE 0]<br />

22.<strong>10</strong>5 MTWAT. [MTAPE 0]<br />

FUNCTION<br />

Stops program execution until all spacing and I/O operations for a<br />

magnetic tape device are completed. Use FILOP. to perform MTWAT. on<br />

an extended I/O channel. Your program should execute this call after<br />

all tape-positioning operations.<br />

CALLING SEQUENCE<br />

MTWAT.<br />

return<br />

channo,<br />

In the calling sequence, the program supplies the channo, which is the<br />

number of a channel initialized for a magtape device.<br />

RETURN<br />

The monitor resumes execution at return after all spacing and<br />

operations for the specified device are completed.<br />

I/O<br />

RELATED CALLS<br />

TAPOP.<br />

COMMON PROGRAMMING ERRORS<br />

Including an error return.<br />

Forgetting to include a comma after the channel number.<br />