24.12.2013 Views

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PISYS. [CALLI 136]<br />

-7 .PCACK<br />

-<strong>10</strong> .PCARI<br />

-11 .PCPDL<br />

An address check occurr.ed; the status word<br />

contains the device name.<br />

An exceptional arithmetic condition occurred.<br />

A pushdown list overflow occurred.<br />

-12 .PCNSP<br />

The DECnet NSP. monitor<br />

occurred. Refer to the NSP.<br />

call<br />

UUO.<br />

interrupt<br />

-13 .PCNXM<br />

-14 .PCAPC<br />

-15 . PCUEJ<br />

-16 .PCXEJ<br />

-17 .PCKSY<br />

-20 .PCDSC<br />

-21 .PCDAT<br />

-22 .PCWAK<br />

-23 .PCABK<br />

-24 .PCIPC<br />

-25 .PCDVT<br />

-26 .PCQUE<br />

A reference to nonexistent memory occurred.<br />

A line-frequency clock tick occurred while the<br />

job was running. Note that this does not mean<br />

an interrupt occurs on every clock tick, but<br />

only on those that occur while the job is being<br />

serviced by the CPU. The status word contains<br />

the date and time in universal format.<br />

A fatal error occurred for the job .<br />

An external condition caused a fatal error for<br />

the job.<br />

A KSYS (end of timesharing) warning occurred;<br />

the status word contains the number of minutes<br />

left until KSYS.<br />

The dataset status changed.<br />

An ATTACH or DETACH monitor call was executed.<br />

For ATTACH the status word contains the<br />

Universal Device Index number for the terminal.<br />

For DETACH the status word contains -1.<br />

A WAKE monitor call was executed; the status<br />

word contains the job number of the waker.<br />

An address break condition occurred.<br />

An IPCF packet is in your job's input queue; the<br />

status word contains the associate variable.<br />

DECnet logging event occurred. Returns DR. xxx<br />

conditions, indicating that an event occurred<br />

that the DECnet management layer must handle.<br />

One or more resources requested by an<br />

ENQ. monitor call is now available; the status<br />

word contains the inclusive OR of the<br />

request-ids of the granted requests.<br />

-27 .PCNET<br />

-30 .PCJBI<br />

The ANF-<strong>10</strong> network topology changed.<br />

obtain the state of the network<br />

NODE. monitor call.<br />

Cross-job interrupt.<br />

You can<br />

using a<br />

-31 .PCDTC<br />

Date/time changed. The offset from the previous<br />

UDT is returned in the status word. This offset<br />

should be added to a previously stored UDT.<br />

22-319

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!