DTE. [CALLI 170]<br />

24 .DTELS<br />

Loads a secondary bootstrap from your job's memory<br />

area, using the PDP-11 bootstrap ROM. This<br />

function must be preceded by the .DTECL (clear)<br />

and .DTEPR (press reload) functions. You must<br />

also use function .DTEDM (dump) before you can<br />

load any bootstrap. The argument list for this<br />

function is:<br />

addr:<br />

XWD<br />

POINT<br />

EXP<br />

cpuno,dteno<br />

16,addr1<br />

length<br />

where addr+l contains a byte pointer indicating<br />

the location of the secondary loader, and length<br />

is the length of the loader, in 16-bit bytes.<br />

25 .DTEDM<br />

Dumps PDP-II memory, using the PDP-l1 bootstrap<br />

ROM. Before you use this function, be sure to use<br />

functions .DTECL (clear) and .DTEPR (press<br />

reload) . You must always dump the PDP-II memory<br />

before you can load a program into its memory.<br />

The argument list for this function is:<br />

addr:<br />

XWD<br />

POINT<br />

EXP<br />

cpuno,dteno<br />

16,addr1<br />

count<br />

where addr+l contains a byte-pointer to the memory<br />

that must be dumped, and where count is the number<br />

of 16-bit bytes to dump from the PDP-11.<br />

26 .DTKPS<br />

Set KLINIK parameters.<br />

use. )<br />

(Not intended for customer<br />

27 .DTKPR<br />

SKIP RETURN<br />

Read KLINIK parameters.<br />

customer use.)<br />

(Not intended for<br />

The function is performed, and any requested value is stored in the<br />

ac.<br />

ERROR RETURN<br />

One of the following error codes is returned in the ac:<br />

Code<br />

Symbol<br />

1 DTENP%<br />

2 DTEUF%<br />

3 DTEDC%<br />

4 DTEAP%<br />

5 DTEPT%<br />

6 DTEDE%<br />

7 DTTTE%<br />

<strong>10</strong> DTEDD%<br />

11 DTEIJ%<br />

12 DTEIB%<br />

13 DTENI%<br />

14 DTEFB%<br />

15 DTENF%<br />

16 DTEFE%<br />

17 DTESE%<br />

20 DTENC%<br />

Error<br />

Not enough privileges.<br />

Illegal function code.<br />

Illegal CPU or DTE number.<br />

Primary protocol already running.<br />

Power fail did not come up.<br />

Doorbell did not clear.<br />

To <strong>TOPS</strong>-I0 error during BOOT sequence.<br />

No response from PDP-II after BOOT sequence.<br />

Illegal job number.<br />

Illegal byte count. .<br />

Front-end device not initialized.<br />

Front-end device in use by another job.<br />

Nonexistent front-end device.<br />

Fatal error on front-end device.<br />

Error starting primary protocol.<br />

No free core for front-end device buffers.<br />