24.12.2013 Views

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

STRUUO [CALLI 50]<br />

6 . FSULK<br />

Tests and sets the software interlock bit<br />

associated with each UFO. This function is used,<br />

along with the . FSUCL function, to control<br />

programs (such as PULSAR and LOGIN) attempting to<br />

modify a UFO at the same time. .FSULK requires<br />

privileges. The argument block for the .FSULK<br />

function is shown b~low.<br />

Word Symbol<br />

o . FSFCN<br />

1 .FSINM<br />

2 .FSIPP<br />

Contents<br />

The function code (.FSULK).<br />

The file structure name<br />

SIXBIT.<br />

The PPN of the UFO.<br />

in<br />

If the interlock bit is set, your program takes<br />

the error return.<br />

7 . FSUCL<br />

Clears the software interlock associated with a<br />

UFO. Once a program has cleared the interlock,<br />

another program may set the interlock (function<br />

. FSULK) and modify the UFO. .FSUCL requires<br />

privileges. The argument block for the .FSUCL<br />

function is shown below:<br />

Word Symbol Contents<br />

0 .FSFCN The function code (.FSUCL) .<br />

1 . FSGNM The file structure name in<br />

SIXBIT.<br />

2 .FSGPP The PPN of the UFO.<br />

<strong>10</strong> .FSETS<br />

Tests error recovery procedures for the monitor<br />

and your programs by causing hard and soft errors<br />

to be simulated on the specified disk unit of the<br />

system. .FSETS requires privileges.<br />

NOTE<br />

This function is obsolete and applies only<br />

to RP<strong>10</strong> and RC<strong>10</strong> controllers.<br />

All error recovery and reporting procedures are<br />

followed through by the monitor as if a real error<br />

had occurred. This function causes the monitor to<br />

enter the simulated hard errors in the BAT block<br />

just as it would enter a real error. Therefore,<br />

field service should be notified of any error<br />

simulations that are being done.<br />

This<br />

and<br />

disk<br />

When<br />

test<br />

function is implemented only for disk packs<br />

should not be attempted for the fixed-head<br />

because the counts will not be decremented.<br />

a unit is removed from the system, the error<br />

sequence is terminated.<br />

22-417

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!