MTIND. [MTAPE <strong>10</strong>1]<br />

22.99 MTIND. [MTAPE <strong>10</strong>1]<br />

FUNCTION<br />

Initializes a channel for industry-compatible mode tape handling.<br />

FILOP. to perform an MTIND. on an extended I/O channel.<br />

Use<br />

In industry-compatible mode, the monitor writes or reads 32 bits in 4<br />

frames of a 9-track magnetic tape, ignoring the low-order 4 bits of<br />

each PDP-<strong>10</strong> word. MTIND. will set a default density to 1600 BPI, or<br />

the highest density allowed on the drive.<br />

The industry-compatible mode remains in effect until the channel is<br />

released, or until you issue the MTDEC. monitor call for the channel.<br />

CALLING SEQUENCE<br />

MTIND.<br />

return<br />

channo,<br />

In the calling sequence, the program supplies the channo, which is the<br />

number of a channel initialized for a magtape device.<br />

RETURN<br />

The device associated with the given channel is initialized for<br />

industry-compatible mode handling.<br />

EXAMPLES<br />

RELATED CALLS<br />

MTIND. <strong>10</strong>,<br />

o<br />

o<br />

FILOP.<br />

TAPOP.<br />

COMMON PROGRAMMING ERRORS<br />

Including an error return when none exists.<br />

Forgetting to include a comma after the channel number.<br />

22-250