PATH. [CALLI 1<strong>10</strong>]<br />

30 PT.DTL<br />

31 PT. I ... IB<br />

32 PT.NEW<br />

33 PT.SYS<br />

34-35 PT.SCN<br />

Set to prevent any change to the<br />

status of LIB, allowing changes<br />

to NEW and SYS without changing<br />

LIB. This flag is useful only<br />

for function code .PTFSL.<br />

Returned to indicate that LIB: is<br />

def1ned for your job. If LIB: is<br />

defined, it will be searched on<br />

~ach structure in your job search<br />

list, after your default path for<br />

each structure in the job search<br />

list has been exhausted in the<br />

attempt to find a file. The LIB<br />

ersatz device name can be defined<br />

using function .PTFSL, or by<br />

setting flag PT. SEA in the LIB<br />

pathological name definition<br />

using function .PTFSN.<br />

Returned to indicate that, when<br />

SYS is specified or implied, the<br />

NEW area [1,5] will be searched<br />

before the SYS area [1,4].<br />

Returned to indicate that SYS<br />

(ersatz device name for [1,4])<br />

will be searched on each<br />

structure in your job search list<br />

after your default path to each<br />

stDucture in the search list has<br />

been exhausted in the attempt to<br />

find a file.<br />

Controls searching of<br />

higher-level directories.<br />

'(Similar to /SCAN switch to<br />

SETSRC program, but overrides the<br />

setting of /SCAN.) The values of<br />

this field can be 0 (use same<br />

scanning st~tus as before the<br />

PATH. call), or one of the<br />

"following:<br />

Value Symbol<br />

Switch Setting<br />

0 Use default<br />

setting.<br />

1 .PTSCN Turns scanning<br />

off.<br />

2 .PTSCY Turns scanning<br />

on.<br />

The scanning status is returned<br />

if you specify a device or<br />

channel number in .PTFCN, or if<br />

you use function .PTFRD. The<br />

status is set using 'function<br />

.PTFSD. These bits are checked<br />

when the path block is given for<br />

LOOKUP, GETSEG, RUN, MERGE., and<br />

FILOP. calls.<br />