24.12.2013 Views

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

TOPS-10 Monitor Calls Manual Volume 2 AA-K039D ... - Trailing-Edge

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GETTAB TABLES<br />

29 F%DSUP<br />

30 F%DQTA<br />

31 F%STR<br />

32 F%5UUO<br />

33 F%PHYO<br />

34 F%SFD<br />

35 F%MOUN<br />

Super USETI/USETO monitor calls.<br />

Disk quotas.<br />

Multiple structures (always set).<br />

Miscellaneous 5-series monitor calls (always set).<br />

Physical devices only (always set).<br />

Subfile directories (SFDs) (always set).<br />

STRUUO monitor call functions (always set).<br />

%FTDSK internal disk parameter flags (more at %FTDS2 below) are as<br />

follows:<br />

Bits<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

32<br />

33<br />

34<br />

35<br />

Symbol<br />

F%SLCK<br />

F%2ATB<br />

F%CBDB<br />

F%LOGI<br />

F%DISK<br />

F%FFRE<br />

F%SWPE<br />

F%DBBK<br />

F%DUFC<br />

F%DETS<br />

F%DMRB<br />

F%DSMC<br />

F%DALC<br />

F%DSTT<br />

F%DHNG<br />

F%DBAD<br />

F%DOPT<br />

Feature<br />

Debug search list code.<br />

2-part access blocks (obsolete, always off)<br />

Debug CB interlock.<br />

LOGIN (defined in S, always on) .<br />

Disk system (defined in S, always on) .<br />

Prevent races in FILFND (obsolete, always off) .<br />

Swap read error recovery (always set).<br />

Bad block marking.<br />

UFD compressing.<br />

Disk error simulator (obsolete, always off).<br />

Multi-RIBs.<br />

Smaller allocation of disk core blocks (obsolete,<br />

always off)<br />

Allocation optimization.<br />

Disk-usage statistics.<br />

Hung disk recovery (always set) .<br />

Disk offline recovery.<br />

Latency optimization (always set).<br />

%FTSCN scanner option feature test flags are as follows:<br />

Bits<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

32<br />

33<br />

34<br />

35<br />

Symbol<br />

F%RP04<br />

F%BDX<br />

F%DCXH<br />

F%TVP<br />

F%TYPE<br />

F%2741<br />

F%CAFE<br />

F%TBLK<br />

F%TPAG<br />

F%DIAL<br />

F%SCLC<br />

F%SCNR<br />

F%MODM<br />

F%630H<br />

F%GP02<br />

F%HDPX<br />

Feature<br />

RP04 support (always set) .<br />

Remote data-entry service.<br />

DC<strong>10</strong>-H (2741 on DC<strong>10</strong>) support (obsolete, always off) .<br />

Fancy vertical positioning.<br />

TYPESET-<strong>10</strong> features on DC76 (obsolete, always off) .<br />

Support for 2741-like termirials (obsolete, always<br />

off) .<br />

DC76 support (always set).<br />

TTY BLANK command.<br />

PAGE and display knowledge.<br />

Auto-dialer.<br />

Special line control (always set) .<br />

Hardware scanner (always set.)<br />

Modem control.<br />

Single-scanner 630.<br />

Modem support (obsolete, always off).<br />

Truly half-duplex terminals (obsolete, always off) .<br />

23-77

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!