<strong>MonitorMagic</strong><br />

Oid2 change per second (Vnew-Vold)/(Elapsed time)<br />

Rate calculation, the result is the change per second of the first object identifier in units per<br />

second.<br />

Oid1 plus Oid2 (V1+V2)<br />

Result equals the sum of the first two object identifiers.<br />

Oid1 plus Oid2 difference (V1new+V2new)-(V1old+V2old)<br />

Result equals the difference between current sum and previous sum value of the first two object<br />

identifiers.<br />

Oid1 plus Oid2 per second {(V1new+V2new)-(V1old+V2old)}/{Elapsed time}<br />

Rate calculation, the result is the change per second of the sum of first two object identifiers in<br />

units per second.<br />

Oid1 minus Oid2 (V1-V2)<br />

Result equals the difference between the first two object identifiers.<br />

Oid1 minus Oid2 difference (V1new-V2new)-(V1old-V2old)<br />

Result equals the difference between current difference and previous difference value of the first<br />

two object identifiers.<br />

Oid1 minus Oid2 change per second {(V1new-V2new)-(V1old-V2old)}/{Elapsed time}<br />

Rate calculation, the result is the change per second of the difference of the first two object<br />

identifiers in units per second.<br />

Oid1 divided by Oid2 (V1/V2)<br />

The value of object identifier 1 divided bu\y the value of object identifier 2. If the value of object<br />

identifier 2 equals zero, the result is zero.<br />

Oid1 times Oid2 (V1 * V2)<br />

The result of the value of object identifier 1 times object identifier 2.<br />

See also:<br />

<strong>MonitorMagic</strong> SNMP support<br />

Snmp get monitor - Overview<br />

Snmp get monitor - Tables<br />

Snmp get monitor - Database support<br />

You can store the data obtained from Snmp get monitors in the <strong>MonitorMagic</strong> database. To<br />

specify the database storage parameters for the Snmp get monitor, see Database - Monitor<br />

data and Database - Changing database storage for multiple items for more information.<br />

For each Snmp get monitor, <strong>MonitorMagic</strong> can only store the result of the specified formula. By<br />

default, the result of the formula equals the value of the first specified object identifier. See Snmp<br />

get monitor - Formula calculation for more information.<br />