12.07.2015 Views

Manual - Famco

Manual - Famco

Manual - Famco

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 6 - Parameter Description [FU2]FU2► SS P-gain24 10024100Input PowerInput Power lossFactory Default: 100 100TimeFU2► SS I-gain25 20025200Motor SpeedFactory Default: 200 200This function is used to permit automatic restarting afterPower ON, Fault Reset, and Instant Power Failurewithout waiting for the motor to stop.The speed search gain should be set after consideringthe inertia moment (GD 2 ) and magnitude of torque of theload. FU2-37 [Load Inertia] must be set at the correctvalue to make this function operate correctly.FU2-22 [Speed Search Select]Setting Range4 th bit 3 rd bit 2 nd bit 1 st bitDescription0 0 0 0 Speed search function does not work0 0 0 1 Speed search during Accelerating0 0 1 0Speed search during a Fault Resetrestarting (FU2-21) and Autorestarting (FU2-26)0 1 0 0Speed search during Instant PowerFailure restarting.1 0 0 0Speed search during Power ONstarting (FU2-20)When FU2-22 is set to ‘1111’, Speed Search works for allconditions.FU2-22 [Speed Search Selection] selects the speedsearch function.FU2-23 [Current Limit Level] is the current that theinverter limits its current rise during speed searching.(The set value is the percentage of FU2-33 [Rated MotorCurrent])FU2-24 [P Gain] is the proportional gain used for speedsearch. Set this value according to load inertia set inFU2-37.FU2-25 [I Gain] is the Integral gain used for speedsearch. Set this value according to load inertia set inFU2-37.Output FrequencyOutput VoltageRelated Functions:[Speed Search Operation]FU2-26: Number of Auto Restart AttemptFU2-27: Delay Time Before Auto RestartFU2►Retry number26 026Factory Default: 0 0FU2►Retry delay27 1.0 secTimeTimeTimeFU2-20 [Power ON Start]FU2-21 [Restart after Fault Reset]FU2-26 ~ FU2-27 [Auto Restart]FU2-30 ~ FU2-37 [Motor Parameters]This function is used to allow the inverter to reset itselffor a selected number of times after a fault has occurred.The inverter can restart itself automatically when a faultoccurs. To use the speed search function during autorestarting set FU2-22 to ‘xx1x’. See FU2-22 ~ FU2-25.When an under voltage (LV) fault, inverter disable (BX)2701.0Factory Default: 1.0 sec 1.0103

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!