Chapter 7 - Options· DB resistor wiring for 15~30HP Built-in DB Unit InverterTH1 TH2B1 B2DB ResistorMax distance between inverter andDB Resistor: 5mP1RSTB1B2UVWIMG24 VAnalog freqoutput 2)(0-10V)FWD Run / StopREV Run / StopFault resetJogFXRXBXRSTJOGP1P2Max Current thruPC: 5mAMulti-function input terminal(I/O-12 Setting: Ext Trip-B)FM5G+FMP3CMDB resistor terminalTerminal descriptionB1, B2 Connect the DB Resistor to Inverter terminal B1, B2.TH1, TH2Thermal sensors provided with the DB resistor.P1 is ON (TH1-TH2 Shorted) at normal (ambient temp) and P1 is OFF (TH1-TH2Open) at overheated status. Connect the thermal sensor to one of the multi-functioninput (P1, P2 or P3, I/O 12-14 setting: Ext Trip-B).171