12.07.2015 Views

Manual - Famco

Manual - Famco

Manual - Famco

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 6 - Parameter Description [APP]☞ The ‘Trv Acc’ terminal set in EXT-30 to EXT-32 is ONduring traverse acceleration time. (Open CollectorOutput)☞ The ‘Trv Dec’ terminal set in EXT-30 to EXT-32 is ONduring traverse deceleration time. (Open CollectorOutput)☞ APP-04 and APP-05 should be set to a value less thanAPP-03. If not, traverse control does not accomplishedcorrectly.APP-06: Traverse Offset (Hi) SettingAPP-07: Traverse Offset (Lo) SettingAPP► Trv Off Hi06 0.0 %06This code makes positive offset during traverseoperation by multi-function input terminal. When the ‘TrvOff Hi’ terminal is ON, the offset frequency is added tothe reference frequency. To use this function, set aterminal out of multi-function input terminals (P1, P2, P3)to ‘Trv Off Hi’ in I/O-12 ~ I/O-14. The offset value isdetermined by,Trv. Off Hi Frequency =(Reference Frequency * Trv. OffHi)/100This code makes negative offset during traverseoperation by multi-function input terminal. When the ‘TrvOff Lo’ terminal is ON, the offset frequency is subtractedfrom the reference frequency. To use this function, set aterminal out of multi-function input terminals (P1, P2, P3)to ‘Trv Off Lo’ in I/O-12 ~ I/O-14. The offset value isdetermined by,Trv. Off Lo Frequency =(Reference Frequency * Trv. OffLo)/100APP-08: Running Auxiliary Motor NumberDisplay0.0Factory Default: 0.0 % 0.0APP► Trv Off Lo07 0.0 %070.0Factory Default: 0.0 % 0.0APP►Aux Mot Run08 008Factory Default: 0 00This code shows how many auxiliary motors are runningby MMC control.APP-09: Starting Auxiliary Motor SelectionAPP►Starting Aux09 109Factory Default: 1 1This code sets the starting auxiliary motor for MMCcontrol.APP-10: Operation Time Display on AutoChangeAPP►Auto Op Time10 00:00This code displays the operation time after Auto Changeis accomplished.APP-11: Start Frequency of Aux. Motor 1APP-12: Start Frequency of Aux. Motor 2APP-13: Start Frequency of Aux. Motor 3APP-14: Start Frequency of Aux. Motor 4The inverter turns on AUX, RLY1, RLY2, and RLY3 in100:00Factory Default: 00:00 00:00APP►Start freq111 49.99 Hz1049.99Factory Default: 49.99 Hz 49.99APP►Start freq212 49.99 Hz1149.99Factory Default: 49.99 Hz 49.99APP►Start freq313 49.99 Hz1249.99Factory Default: 49.99 Hz 49.99APP►Start freq414 49.99 Hz1349.99Factory Default: 49.99 Hz 49.9914147

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!