12.07.2015 Views

Manual - Famco

Manual - Famco

Manual - Famco

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

D RVPROGENTiS5VARIABLE FREQUENCY DRIVED RVPROGENTFU1W ARN INGRiskofI•juryorE•ectricShockRiskofE•ectricShockRiskofE•ectricShockFU1FU2LE -200ST OPRESETiS5E XTSHIF TESCRUNVARIABLE FREQUENCY DRIVEFU2LE -200ST OPRESETI /OW ARN INGRiskofI•juryorE•ectricShockRiskofE•ectricShockRiskofE•ectricShockI /OE XTSHIF TESCRUNChapter 6 - Parameter Description [FU2]This must be set when using an external DB resistor.The duty is calculated by ‘%ED=Decel time * 100 /(Accel time + Steady speed time + Decel time + Stopstatus time)’.FU2-79: Software VersionFU2► S/W Version79 Ver X.XDisplays the software version. This will vary dependingon software version integrated.FU2-81 ~ FU2-90: 2 nd Motor Related FunctionsThese functions are displayed only when one of themultifunction inputs is set at ‘2nd func’ in I/O-12 to I/O-14.When using two motors with an inverter by exchangingthem, different values can be set for the 2 nd motor byusing the multifunction input terminal.Following table is the 2 nd functions corresponding to the1 st functions.2 nd Functions 1 st Functions DescriptionFU2-81 DRV-01[2nd Acc time] [Acc. time]Acceleration timeFU2-82 DRV-02[2nd Dec time] [Dec. time]Deceleration timeFU2-83 FU1-21[2nd BaseFreq] [Base freq]Base FrequencyFU2-84 FU1-29[2nd V/F] [V/F Pattern]Volts/Hz modeFU2-85 FU1-27[2nd F-boost] [Fwd Boost]Forward torque boostFU2-86 FU1-28[2nd R-boost] [Rev Boost]Reverse torque boostFU2-87 FU1-60[2nd Stall] [Stall Level]Stall prevention levelFU2-88 FU1-51[2nd ETH 1min] [ETH 1min]ETH level for 1 minuteFU2-88 FU1-52[2nd ETH cont] [ETH cont]ETH level for continuousFU2-90 FU2-33[2nd R-Curr] [Rated-Curr]Motor rated current79X.XFactory Default: Ver. X.X X.X• Exchange the motor connection from the 1 st motor to the2 nd motor or the opposite when the motor is stopped.Over voltage or over current fault can occur when themotor connection is exchanged during operation.• The ‘User V/F’ function of FU1-29 [V/F Pattern] is usedfor both the 1st motor and the 2nd motor.FU2-91: Parameter ReadFU2-92: Parameter WriteFU2► Para. read91 --- No ---Factory Default:NoFU2► Para. write92 --- No ---Factory Default:NoThis is useful for programming multiple inverters to havesame parameter settings. The LCD keypad can read(upload) the parameter settings from the invertermemory and can write (download) them to otherinverters. This function is only available with LCDkeypad.FU2► Para. read91 --- Yes ---Parameter UploadParameter DownloadFU2► Para. write92 --- Yes ---• The 1 st functions are applied if the multifunction terminalis not defined to ‘2nd Func’ or if it is not ON. The 2 ndfunction parameters are applied when the multifunctioninput terminal set to ‘2nd Func’ is ON. Parameters notlisted on the table above are applied to the 2 nd motor asto the 1 st motor.116

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!