Chapter 6 - Parameter Description [FU1]Output FrequencyOutput CutoffBy introducing a DC voltage to the motor windings thisfunction stops the motor immediately. Selecting ‘DC-Brake’ in FU1-07 activates FU1-08 through FU1-11.Output VoltageOutput CutoffStop CommandFX-CM ON[[Stop Mode: ‘Free-run’]TimeTimeTimeFU1-08 [DC Injection Braking Frequency] is thefrequency at which the inverter starts to output DCvoltage during deceleration.FU1-09 [DC Injection Braking On-delay Time] is theinverter output blocking time before DC injection braking.FU1-10 [DC Injection Braking Voltage] is the DC voltageapplied to the motor and is based on FU2-33 [RatedCurrent of Motor].FU1-11 [DC Injection Braking Time] is the time the DCcurrent is applied to the motor.Output FrequencyFU1-08: DC Injection Braking FrequencyFU1-09: DC Injection Braking On-delay TimeFU1-10: DC Injection Braking VoltageFU1-11: DC Injection Braking TimeFU1-08[DCBr Freq]Output VoltageTimeFU1► DcBr freq08 5.00 Hz085.00Factory Default: 5.00 Hz 5.00FU1► DcBlk time09 0.10 sec090.10Factory Default: 0.10 sec 0.10FU1-10[DCBr Value]FX-CMONt1Stop Command[DC Injection Braking Operation]t1: FU1-09t2: FU1-11t2TimeTimeFU1► DcBr value10 50 %1050Factory Default: 50 % 50FU1► DcBr time11 1.0 sec111.0Factory Default: 1.0 sec 1.089