Chapter 5 - Parameter ListCodeFU1-27FU1-28DescriptionTorque Boost in ForwardDirectionTorque Boost in ReverseDirectionKeypad DisplayFU1-29 Volts/Hz Pattern V/F pattern 29Setting RangeLCD 7-Segment LCD 7-SegmentUnitsFactoryDefaultAdj.DuringRunFwd boost 27 0 to 15 [%] 0.1 2.0 [%] NoRev boost 28 0 to 15 [%] 0.1 2.0 [%] NoLinear 0Square 1User V/F 2Page- Linear No 93FU1-30 16 User V/F – Frequency 1 User freq 1 30 0 to FU1-20 0.01 15.00 [Hz] NoFU1-31 User V/F – Voltage 1 User volt 1 31 0 to 100 [%] 1 25 [%] NoFU1-32 User V/F – Frequency 2 User freq 2 32 0 to FU1-20 0.01 30.00 [Hz] NoFU1-33 User V/F – Voltage 2 User volt 2 33 0 to 100 [%] 1 50 [%] NoFU1-34 User V/F – Frequency 3 User freq 3 34 0 to FU1-20 0.01 45.00 [Hz] NoFU1-35 User V/F – Voltage 3 User volt 3 35 0 to 100 [%] 1 75 [%] NoFU1-36 User V/F – Frequency 4 User freq 4 36 0 to FU1-20 0.01 60.00 [Hz] NoFU1-37 User V/F – Voltage 4 User volt 4 37 0 to 100 [%] 1 100 [%] NoFU1-38Output VoltageAdjustmentVolt control 38 40 to 110 [%] 0.1 100.0 [%] No 94FU1-39 Energy Save Level Energy save 39 0 to 30 [%] 1 0 [%] Yes 94FU1-50Electronic ThermalSelectionElectronic Thermal LevelFU1-5117 for 1 MinuteFU1-52FU1-53Electronic Thermal Levelfor ContinuousElectronic ThermalCharacteristic Selection(Motor Type)ETH select 50No 0Yes 1- No YesETH 1 min 51 FU1-52 to 200 [%] 1 180 [%] YesETH cont 52 50 to FU1-51 (Maximum 150%) 1 120 [%] YesMotor type 53Self-cool 0Forced-cool 1- Self-cool YesFU1-54 Overload Warning Level OL level 54 30 to 150 [%] 1 150 [%] YesFU1-55Overload Warning HoldTimeFU1-56 Overload Trip Selection OLT select 56OL time 55 0 to 30 [sec] 0.1 10.0 [sec] YesNo 0Yes 1- Yes YesFU1-57 Overload Trip Level OLT level 57 30 to 200 [%] 1 180 [%] YesFU1-58 Overload Trip Delay Time OLT time 58 0 to 60 [sec] 1 60.0 [sec] YesFU1-59Stall Prevention ModeSelectionStall prev. 59000 to 111(Bit Set)bit 000 NoFU1-60 Stall Prevention Level Stall level 60 30 to 250 [%] 1 180 [%] NoFU1-99 Return Code Not displayed 99 Not available 1 - 1 - 98949596969716Code FU1-30 through FU1-37 appears only when FU1-29 is set to ‘User V/F’.17Code FU1-51 through FU1-53 appears only when FU1-50 is set to ‘Yes’.59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!