12.07.2015 Views

Manual - Famco

Manual - Famco

Manual - Famco

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 5 - Parameter ListCodeI/O-45DescriptionFault Output RelaySetting (30A, 30B, 30C)Keypad DisplaySetting RangeLCD 7-Segment LCD 7-SegmentRelay mode 45000 to 111(Bit Set)UnitsFactoryDefaultAdj.DuringRunPage- 010 Yes 133I/O-46 26 Inverter Number Inv No. 46 1 to 31 1 1 Yes 133I/O-47 Baud Rate Baud rate 471200 bps 02400 bps 14800 bps 29600 bps 319200 bps 4- 9600 bps Yes 133None 0I/O-48Operating selection atLoss of Freq. ReferenceLost command 48FreeRun 1Stop 2- None Yes133I/O-49Waiting Time after Lossof Freq. ReferenceTime out 49 0.1 to 120 [sec] 0.1 1.0 [sec] YesI/O-50Auto (Sequence)Operation selectionAuto mode 50None 0Auto-A 1Auto-B 2- None NoI/O-51Sequence NumberSelectionSeq select 51 1 to 5 1 1 Yes134I/O-52The Number of Steps ofSequence Number #Step number 52 1 to 8 1 2 YesI/O-53 271 st Step Frequency ofSequence 1Seq1 / 1F 53 0.01 to FU1-20 0.01 11.00 [Hz] YesI/O-54Transient Time to 1 st Stepof Sequence 1Seq1 / 1T 54 0.1 to 6000 [sec] 0.1 1.1 [sec] YesI/O-55I/O-56I/O-57I/O-58I/O-59I/O-60Steady Speed Time at 1 stStep of Sequence 1Seq1 / 1S 55 0.1 to 6000 [sec] 0.1 1.1 [sec] YesMotor Direction of 1 stReverse 0Seq1 / 1D 56Step of Sequence 1Forward 1- Forward Yes1 st Step Frequency ofSequence 2Seq1 / 2F 57 0.01 to FU1-20 0.01 21.00 [Hz] YesTransient Time to 1 st Stepof Sequence 2Seq1 / 2T 58 0.1 to 6000 [sec] 0.1 1.1 [sec] YesSteady Speed Time at 1 stStep of Sequence 2Seq1 / 2S 59 0.1 to 6000 [sec] 0.1 1.1 [sec] YesMotor Direction of 1 stReverse 0Seq1 / 2D 60Step of Sequence 2Forward 1- Forward YesI/O-85 Step Frequency 8 Step freq-8 85 0 to FU1-20 0.01 20.00 [Hz] YesI/O-86 Step Frequency 9 Step freq-9 86 10.00 [Hz] YesI/O-87 Step Frequency 10 Step freq-10 87 20.00 [Hz] YesI/O-88 Step Frequency 11 Step freq-11 88 30.00 [Hz] YesI/O-89 Step Frequency 12 Step freq-12 8940.00 [Hz] Yes13513512626Code I/O-46 through I/O-49 are used in Option Board like RS485, Device, Net and F-net etc.27The ‘Seq#’ of code I/O-53 through I/O-60 varies according to the sequence number selected in I/O-51.The parameter code may be extended to I/O-84 depending the number of steps set in I/O-52 because the steps can be set up to 8.67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!