Chapter 6 - Parameter Description [APP]¨ Abnormal motor can be skipped from running byusing the multi-function input terminals (P1, P2, P3, andP4). If a multi-function terminal is opened, the inverterstops all running motors and restarts operation with onlynormal motors except the abnormal motor. (Refer toAPP-29)¨ Sleep function is initiated when flow demand is low.Inverter stops motor when the motor runs below SleepFrequency (APP-24) during Sleep Delay Time (APP-23).While in the sleep state, inverter keeps monitoring andinitiates Wake-Up function when the real value of thecontrolling amount has decreased below the Wake-Uplevel (APP-25).☞ Note: Only one auxiliary motor can be connected withAUX terminal on control terminal strip without using MMCOption Board.Related Functions:APP-08 to APP-31 [MMC Parameters]DRV-04 [Frequency Mode]FU2-47 [PID Operation Selection]I/O-01 to I/O-10 [Analog Signal Input]EXT 15 to EXT21 [Pulse Input Signal]I/O-12 to I/O-14 [Multi-Function Input]EXT-30 to EXT-32 [Multi-Function Output][Draw]: This is a kind of Open-Loop Tension Control.This is used to maintain constant tension of material withthe speed difference between main motor andsubordinate motor.Related Functions:APP-02: Traverse AmplitudeAPP►Trv. Amp[%]02 0.0%APP-32 to APP-33 [Draw Parameters]DRV-04 [Frequency Mode]I/O-01 to I/O-10 [Analog Signal Input]EXT 06 to EXT-10 [Analog Input Setting]I/O-12 to I/O-14 [Multi-Function Input]EXT-02 to EXT-04 [Multi-Function Input]02This code sets the frequency amplitude of traverseoperation. The value is the percentage of referencefrequency. The output value is determined by,Trv. Amp Frequency = (Reference Freq. * Trv. Amp)/100APP-03: Traverse Scramble Amplitude0.0Factory Default: 0.0% 0.0InputPowerV1V2IiS5AUXMMC BoardRLY1RLY2RLY3Aux. Motor 1M1Aux. Motor 2M2Aux. Motor 3M3Aux. Motor 4MMain Motor[MMC Diagram]M4APP►Trv. Scr[%]03 0.0%This code sets the frequency amplitude of scrambleoperation. The output value is determined by,Trv. Scr Frequency = (Trv. Amp Frequency * (100 - Trv.Scr))/100APP-04: Traverse Accel TimeAPP-05: Traverse Decel Time030.0Factory Default: 0.0% 0.0APP►Trv Acc Time04 2.0 sec042.0Factory Default: 2.0 sec 2.0APP►Trv Dec Time05 3.0 sec053.0Factory Default: 3.0 sec 3.0Sets the acceleration and deceleration time for traverseoperation.146

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!