CONTROLOPERATIONProtectionDisplayEnvironmentControl MethodFrequency SettingResolutionFrequency AccuracyV/F RatioOverload CapacityV/F Control, Sensorless Vector Control, Sensored Vector Control (Velocity, Torque) SelectableDigital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)Analog Reference: 0.03 Hz / 60 HzDigital: 0.01 % of Max. Output FrequencyAnalog: 0.1 % of Max. Output FrequencyLinear, Squared Pattern, User V/F150 % of Rated Current for 1 Min., 200% of Rated Current for 0.5 sec. (Characteristic isInversely Proportional to Time)Torque Boost<strong>Manual</strong> Torque Boost (0 ~ 15 %), Auto Torque BoostOperation Method Key / Terminal / Communication OperationFrequency Setting Analog: 0 ~ 10V / 4 ~ 20mA / Additional port for Sub-Board (0 ~ 10V)Digital: KeypadStart SignalForward, ReverseInput SignalOutput SignalMulti-StepMulti Step Accel/DecelTimeEmergency StopJogAuto OperationFault ResetOperating StatusFault OutputIndicatorOperation FunctionInverter TripInverter AlarmMomentary Power LossKeypadOperationInformationTrip InformationAmbient TemperatureStorage TemperatureAmbient HumidityAltitude - VibrationApplication SiteCooling MethodUp to 8 Speeds can be Set (Use Multi-Function Terminal)0 ~ 6,000 sec, Up to 4 Types can be Set and Selected for Each Setting (Use Multi- FunctionTerminal). Accel/Decel Pattern: Linear, U-Curve, S-CurveInterrupts the Output of InverterJog OperationOperates from Internal Sequence by Setting Multi-Function Terminal (5 Way * 8 Step)Trip Status is Removed when Protection Function is ActiveFrequency Detection Level, Overload Alarm, Stalling, Over Voltage, Under Voltage, InverterOverheating, Running, Stop, Constant Speed, Inverter By-Pass, Speed Searching, Auto-Operation Step, Auto-Operation SequenceContact Output (30A, 30C, 30B) – AC250V 1A, DC30V 1AChoose 1 from Output Frequency, Output Current, Output Voltage, DC Voltage, Output Torque(Output Voltage: 0 ~ 10V)DC Braking, Frequency Limit, Frequency Jump, Second Function, Slip Compensation, ReverseRotation Prevention, Auto Restart, Inverter By-Pass, Auto-Tuning, PID ControlOver Voltage, Under Voltage, Over Current, Fuse Open, Ground Fault, Inverter Overheating,Motor Overheating, Output Phase Open, Overload Protection, External Fault 1, 2,Communication Error, Loss of Speed Command, Hardware Fault, Option Fault, Overspeed,M/C Fail etc.Stall Prevention, Overload Alarm, Temperature Sensor FaultAuto Restart function activated when FU2-21 [Restart after fault reset] set to 1 (Yes)Output Frequency, Output Current, Output Voltage, Frequency Value Setting, OperatingSpeed, DC Voltage, Output TorqueIndicates a Fault when the Protection Function activates, Retains Up to 5 Faults-10 °C ~ 40 °C (14 °F ~ 104 °F), CE Certification: 41 °F ~ 104 °F (5 °C ~ 40 °C)-20 °C ~ 65 °C (-4 °F ~ 149 °F)Less Than 90 % RH Max. (Non-Condensing), CE Certification: 5 ~85% (Non-Condensing)Below 1,000m or 3,300ft · Below 5.9m/sec 2 (=0.6g)No Corrosive Gas, Combustible Gas, Oil Mist, or DustForced Air Cooling5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!