Figure 4.3 Failure surfaces for compressive loading on piles.<br />

Bearing capacity (kN)<br />

300<br />

250<br />

200<br />

200 × 215 mm concrete<br />

(Gothenburg)<br />

Resistance of piles to compressive loads 153<br />

Failure surface in<br />

shaft friction<br />

Failure surface<br />

in end bearing<br />

150<br />

15<br />

100<br />

350 × 150 mm tapered timber (Drammen)<br />

10<br />

50<br />

0<br />

300 × 125 mm I-Beam<br />

(Gothenburg)<br />

150 mm (6 in) steel tube (San Francisco)<br />

5<br />

1 5 10 50<br />

Time after driving (days)<br />

100<br />

500 1000<br />

Figure 4.4 Gain in bearing capacity with increasing time after driving of piles into soft clays.<br />

A further simplifying assumption is made that ��h is proportional to the vertical effective<br />

overburden pressure . Thus<br />

� s � K�� vo tan � r<br />

�� vo<br />

30<br />

25<br />

20<br />

Bearing capacity (tons)<br />

(4.6)<br />

The value of K is constantly changing throughout the period of installation of the pile <strong>and</strong><br />

its subsequent loading history. In the case of a driven pile in a stiff clay K is initially very<br />

high, as a result of the energy transmitted by the hammer blows required to displace the clay<br />

around the pile. However, at this time �� vo is very low or even negative due to the high<br />

pore-water pressures induced by the pile driving. In the case of a bored pile, K is low as the

Hooray! Your file is uploaded and ready to be published.