248 <strong>Pile</strong> groups under compressive loading<br />

Values of the shape factors s c <strong>and</strong> s � for centrally applied vertical loading are obtained<br />

from Figure 5.7, <strong>and</strong> s q from the equation:<br />

s q � s c(s c � 1)<br />

N q<br />

(5.2)<br />

Inclined loading is considered in relation to the effective breadth B� <strong>and</strong> the effective<br />

length L� of the equivalent block foundation. The plan dimensions of the block, as derived<br />

by Meyerhof (5.5) , are shown in Figure 5.8. Thus for loading in the direction of the breadth:<br />

B��B – 2e x<br />

where e x is the eccentricity of loading in relation to the centroid of the base.<br />

Similarly,<br />

L��L – 2e y<br />

The shape factors s are modified for inclined loading by the equations:<br />

(5.3a)<br />

(5.3b)<br />

s CB � 1 �0.2i CB B�/L� (5.4)<br />

s CL � 1 �0.2i CL L�/B� (5.5)<br />

s qB � 1 �sin �i qB B�/L� (5.6)<br />

s qL � 1 �sin �i qL L�/B� (5.7)<br />

s �B � 1 – 0.4i �B B�/L� (5.8)<br />

s � L � 1 – 0.4i �L L�/B� (5.9)<br />

Where B� is less than L�, approximate values of the shape factors for centrally applied<br />

vertical loading which are sufficiently accurate for most practical purposes are<br />

Shape of base s c s q s �<br />

Continuous strip 1.0 1.0 1.0<br />

Rectangle 1�0.2 B/L 1�0.2 B/L 1–0.4 B/L<br />

Square 1.3 1.2 0.8<br />

Circle (diameter B) 1.3 1.2 0.6<br />

Values of the depth factor d c are obtained from Figure 5.9. The values on the right-h<strong>and</strong><br />

side of the figure are for D � infinity. d q is obtained from<br />

d q � d c � 1<br />

N q<br />

(5.10)<br />

The depth factor d � can be taken as unity in all cases, also when � � 0 º , d q � 1.0. Where<br />

� is greater than 25 º d q can be taken as equal to d c. A simplified value of d c <strong>and</strong> d q where �<br />

is less than 25 º is 1�0.35 D/B. The use of the depth factors assumes that the soil above<br />

foundation level is not significantly weaker in shear strength than that of the soil below this<br />

level. However, in the case of pile groups, the piles are usually taken down through weak<br />

soils into stronger material, when either the depth factors should not be used or the depth