25.12.2012 Views

Pile Design and Construction Practice, Fifth edition

Pile Design and Construction Practice, Fifth edition

Pile Design and Construction Practice, Fifth edition

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

160 Resistance of piles to compressive loads<br />

Adhesion factor a<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0<br />

Reduced values for driven<br />

piles where L < 10B <strong>and</strong> till<br />

is overlain by soft clay<br />

Driven <strong>and</strong> driven <strong>and</strong> cast-in-place piles<br />

Bored piles<br />

60 80 100 120<br />

Undrained shear strength Cu , kN/m2 140 160 180 200 220<br />

Figure 4.8 Adhesion factors for piles in glacial till (after Weltman <strong>and</strong> Healy 4.7 ).<br />

length of the driving tube if an enlarged detachable shoe is used to close its base) becomes filled<br />

with concrete. The tube, while being driven, drags down a skin of soft clay or s<strong>and</strong>y soil for a<br />

few diameters into the stiff clay <strong>and</strong> it is quite likely that this skin will remain interposed<br />

between the concrete <strong>and</strong> the soil, i.e. the skin is not entirely pulled out by adhering to the tube.<br />

However, in one important aspect there is a difference between the driven, <strong>and</strong> the driven <strong>and</strong><br />

cast-in-place pile in that water migrates from the unset concrete into the clay <strong>and</strong> softens it for<br />

a limited radial distance. This aspect is discussed in greater detail in Section 4.2.3. Thus the<br />

adhesion factor for a driven <strong>and</strong> cast-in-place pile in a stiff clay may be slightly less than that<br />

for a driven pile in corresponding soil conditions. It will probably be greater over the length in<br />

a soft clay, however, since the concrete slumps outwards as the tube is withdrawn, producing an<br />

increase in effective shaft diameter.<br />

The results of a number of loading tests on driven <strong>and</strong> driven <strong>and</strong> cast-in-place piles in<br />

glacial till have been reviewed by Weltman <strong>and</strong> Healy (4.7) . There appeared to be little difference<br />

in the �–c u relationship for either type of pile. They produced the design curves shown<br />

in Figure 4.8 for the two types of driven pile including a curve for piles driven a short penetration<br />

into stiff glacial till overlain by soft clay. Their review also included a study of the<br />

shaft friction on bored piles in glacial till.<br />

Trenter (4.8) recommended using the Weltman <strong>and</strong> Healy relationships <strong>and</strong> stated that it is<br />

essential to obtain 100 mm samples of the till suitable for strength tests.<br />

When using the EC7 recommendations to determine the ultimate limit state resistance of<br />

driven <strong>and</strong> cast-in-place piles, the procedure described in Section 4.2.1 should be followed.<br />

Compliance with the shaft dimension tolerances in Table 4.9 should be observed.<br />

4.2.3 Bored <strong>and</strong> cast-in-place non-displacement piles<br />

The installation of bored piles using the equipment <strong>and</strong> methods described in Sections 3.3.1<br />

to 3.3.6 <strong>and</strong> 3.4.6 causes changes in the properties of the soil on the walls of the pile borehole<br />

which have a significant effect on the frictional resistance of the piles. The effect of<br />

drilling is to cause a relief of lateral pressure on the walls of the hole. This results in swelling<br />

of the clay <strong>and</strong> there is a migration of pore water towards the exposed clay face. If the borehole<br />

intersects water-filled fissures or pockets of silt the water will trickle down the hole <strong>and</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!