292 <strong>Pile</strong> groups under compressive loading<br />

Checking for compliance with EC7, the stability of the individual pile is calculated using<br />

the procedure described in Section 4.2.3. The calculations are not included in this example.<br />

The same procedure is used for checking the equivalent large-diameter pile for compliance.<br />

The partial factors are as follows:<br />

For actions (Table 4.1: Set A1, permanent unfavourable � 1.35, variable unfavourable � 1.5<br />

Set A2, permanent unfavourable � 1.0, variable unfavourable � 1.3<br />

<strong>Design</strong> value of actions Set A1, F d � (1.35 �250 �1 � 5 �110) �70 � 35175 kN<br />

for Set A2 � (1.0 �250 �1.3 �110) �70 � 27510 kN<br />

Soil parameter resistances for undrained shear strengths (Table 4.2): M1 � 1.0, M2 � 1.4<br />

Base resistances for bored piles (Table 4.4), R1 � 1.25, R2 � 1.1, R3 � 1.0<br />

Shaft resistances for bored piles (Table 4.4), R1 � 1.0, R2 � 1.1, R3 � 1.3<br />

Combined resistances (Table 4.4), R1 � 1.15, R2 � 1.1, R3 � 1.0<br />

The correlation factor � 3 in Table 4.6 for mean values of c u <strong>and</strong> three test profiles is divided<br />

by 1.1 because the pile loads on the group will be redistributed by a stiff pile cap. Therefore<br />

correlation factor for mean strengths � 3 � 1.33/1.1 � 1.21.<br />

Calculating for design approach DA1, Combination1 (Sets A1 � M1 � R1), an adhesion<br />

factor of 0.45 will be used for the concrete–soil interface of the equivalent pile.<br />

Mean group resistance of pile � 9 �80 �65.34 �0.45 �85 �177.6<br />

� 47045 �6793 � 53838 kN<br />

Characteristic group resistance of pile � R ck � 53838/1.21 � 44 494 kN<br />

<strong>Design</strong> value of combined resistance � R cd � 44494/1.0�1.15 � 38690 kN<br />

which is greater than the design action of 35125 kN.<br />

For design approach DA1, Combination 2 (Sets A2�M2�R1): R cd�44 494/1.4 �1.0<br />

� 31781 kN<br />

(�27510 kN)<br />

Checking the equivalent pile for separate shaft <strong>and</strong> base resistances:<br />

For DA1 Combination 1, R cd � 47045/1.21�1.0�1.25�6793/1.21�1.0�1.0<br />

� 31104�5 614�36718 kN (�35175 kN)<br />

For DA1 Combination 2, R cd � 47045/1.21 �1.4 �1.25�6793/1.21 �1.4 �1.0<br />

�26227 kN (�27510 kN)<br />

The lowest design resistance of the equivalent large-diameter pile from the above calculations<br />

is 26227 kN; this can be compared with the ultimate bearing capacity of the block foundation<br />

calculated by the method in Sections 5.1 <strong>and</strong> 5.21 of 98125 kN when divided by a nominal<br />

safety factor of 2.5 gives an allowable bearing capacity of 39250 kN. This shows that for the<br />

particular group dimensions of Example 5.1, the EC7 concept of an equivalent large-diameter<br />