178 Resistance of piles to compressive loads<br />

Cone resistance (qc ) (MN/M2 ) Cone resistance (qc ) (MN/M2 (a) (b)<br />

)<br />

Depth below ground level (m)<br />

0<br />

5<br />

10<br />

15<br />

20<br />

Lower<br />

bound curve<br />

Average curve<br />

The method generally used in the Netherl<strong>and</strong>s is to take the average cone resistance<br />

over a depth of up to four pile diameters below the pile toe, <strong>and</strong> the average eight pile<br />

diameters above the toe as described by Meigh (4.25) qc�2 .<br />

The ultimate base resistance is then<br />

q ub � q c�1 � q c�2<br />

2<br />

5 10<br />

Determining q c from average<br />

<strong>and</strong> lower bound q c /depth<br />

curves<br />

Soft silty clay<br />

Loose<br />

becoming<br />

medium<br />

dense<br />

s<strong>and</strong><br />

15 5 10<br />

0<br />

Path for<br />

determining q c–1<br />

Method used in the Netherl<strong>and</strong>s<br />

for obtaining base resistance<br />

(4.19)<br />

The shape of the cone-resistance diagram is studied before selecting the range of depth<br />

below the pile to obtain . Where the qc increases continuously to a depth of 4D below<br />

the toe, the average value of is obtained only over a depth of 0.7D. If there is a sudden<br />

decrease in resistance between 0.7D <strong>and</strong> 4D the lowest value in this range should be selected<br />

for (Figure 4.18b). To obtain the diagram is followed in an upward direction<br />

<strong>and</strong> the envelope is drawn only over those values which are decreasing or remain constant<br />

at the value at the pile toe. Minor peak depressions are again ignored provided that they<br />

do not represent clay b<strong>and</strong>s; values of qc higher than 30 MN/m2 qc � 1<br />

qc�1 qc�1 qc�2 are disregarded over the<br />

4D – 8D range.<br />

5<br />

10<br />

15<br />

20<br />

Path for<br />

determining q c–2<br />

Figure 4.18 Use of static cone penetration tests (CPT) to obtain design values of average cone<br />

resistance ( ) in coarse soils.<br />

q c<br />

<strong>Pile</strong><br />

D<br />

8D<br />

4D<br />

15<br />

q c�1