Resistance of piles to compressive loads 211<br />

Table 4.19 Presumed safe vertical bearing stress for foundations on horizontal ground in<br />

Hong Kong<br />

Category Weathering Total core Uniaxial compression Equivalent point Presumed<br />

grade recovery strength (MN/m 2 ) load index strength bearing stress<br />

(%) (MN/m 2 ) (MN/m 2 )<br />

1(a) �<br />

II �95 of grade �50 �2 7.5<br />

1(b) � II-III �85 of grade �25 �1 5<br />

1(c) �III-IV<br />

�50 of grade — — 3<br />

Notes<br />

Category 1(a): Fresh to slightly decomposed, strong.<br />

Category 1(b): Slightly to moderately decomposed, moderately strong.<br />

Category 1(c): Moderately decomposed, moderately strong to moderately weak.<br />

The factor � should be based on SPT N-values. For low values of N (less than or equal<br />

to 10) or a cone resistance q c between 2 <strong>and</strong> 4 MN/m 2 , <strong>and</strong> in the absence of pile test<br />

results, � should be taken as 0.45 throughout. Where N is greater than 10, or q c greater<br />

than 4 MN/m 2 , <strong>and</strong> in the absence of flints, � is taken as 0.8 throughout. The allowable<br />

pile load P a should be determined by using the partial factors in equation 4.42.<br />

Throughout reports 574 <strong>and</strong> PR86 it is emphasized that load testing is desirable at some<br />

stage as a means of confirming load capacity, <strong>and</strong> achieving economy in design. It is pointed<br />

out that a single test made to 3 times the working load is a much better aid to judgement than<br />

two tests to 1.5 times the working load.<br />

For granites <strong>and</strong> volcanic rocks, the practice in Hong Kong is to relate the allowable base<br />

bearing pressure for bored piles to the weathering grade of the decomposed material. The<br />

recommendations of the Government Geotechnical Office (4.45) as quoted by Ng et al. (4.59)<br />

are shown in Table 4.19.<br />

The Hong Kong Government recommends that completely weathered granite should be<br />

treated as a soil. Also the rock socket shaft friction in weak to moderately weak <strong>and</strong> strong<br />

to moderately strong granites should be determined from correlation with the uniaxial compression<br />

strength of sedimentary rocks using the method of Horvath et al. (4.50) Ng et al. (4.59)<br />

point out that observations made in loading tests in granites suggest that the value for b in<br />

equation 4.45 of 0.2 is appropriate.<br />

4.7.4 The settlement of the single pile at the working<br />

load for piles in rocks<br />

The effects of load transfer from shaft to base of piles on the pile head settlements have<br />

been discussed by Wyllie (4.39) . Because of the relatively short penetration into rocks which<br />

is needed to mobilize the required total pile resistance, the simpler methods of determining<br />

pile head settlement described in Section 4.6 are suitable in most cases. For piles having<br />

base diameters up to 600 mm the settlement at the working load should not exceed 10 mm<br />

if a safety factor of 2.5 has been applied to the ultimate bearing capacity.<br />

The settlement of large diameter piles can be calculated from equation 4.38. The modulus<br />

of deformation of the rock below the pile toe can be obtained from plate bearing or<br />

pressuremeter tests or from empirical relationships developed between the modulus, the