318 <strong>Pile</strong>s to resist uplift <strong>and</strong> lateral loading<br />

diameter of the anchor <strong>and</strong> the influence of the bottom compression fitting in short anchors.<br />

The anchor diameter is of significance since with large-diameter high-capacity anchors there<br />

is an appreciable diminution of diameter caused by the inward radial strain that occurs under<br />

the tensile load. This creates a tendency to weaken the bond between the steel <strong>and</strong> the grout.<br />

Specifications for anchorage materials <strong>and</strong> grouting cements <strong>and</strong> recommendations<br />

for the bond strength at the grout to tendon interface are given in British St<strong>and</strong>ard 8081,<br />

Code of <strong>Practice</strong> for Ground Anchors. This code provides a wealth of useful <strong>and</strong> practical<br />

information on the design, installation, <strong>and</strong> testing of anchors in soils <strong>and</strong> rock. The code<br />

recommendations for ultimate bond strength are<br />

Plain bar not greater than 1 N/mm 2<br />

Clean str<strong>and</strong> or deformed bar not greater than 2 N/mm 2<br />

Locally noded str<strong>and</strong> not greater than 3 N/mm 2<br />

Mixes of pumpable normal Portl<strong>and</strong> cement grout have compressive strengths in the<br />

range of 14 to 21 N/mm 2 at 3 days. Special grouts are formulated for injection into the<br />

annulus between an anchor <strong>and</strong> a tubular pile or between a pile <strong>and</strong> a surrounding sleeve.<br />

The grouts incorporate plasticizers, exp<strong>and</strong>ing agents <strong>and</strong> fibrous bonding materials. By<br />

adopting a water/cement ratio of about 0.5 compressive strengths of the order of 24 N/mm 2<br />

are attainable at 3 days. Alternatively for marine work a mix consisting of 100 parts of API<br />

Oilwell B cement to 34 parts of seawater will develop a characteristic cube strength of about<br />

22 N/mm 2 at 3 days. However, when such special grouts are used to transfer the load<br />

between large-diameter piles <strong>and</strong> a surrounding sleeve, correspondingly high bond stresses<br />

cannot be achieved. This is because of the shrinkage of the grout in the relatively wide annulus<br />

<strong>and</strong> the diminution in the diameter of the inner member due to the inward radial strain<br />

when under tensile load.<br />

The transfer of load from a pile to the sleeve can be effected wholly through shear keys<br />

formed on the inner surface of the sleeve, <strong>and</strong> outer surface of the pile, <strong>and</strong> these should be<br />

in the form of beads of weld metal or welded-on steel strips.<br />

The ultimate grout to steel bond strength on the surface of tubular piles on pile sleeves<br />

either with or without mechanical shear connectors can be calculated by an equation<br />

recommended by the UK Department of Energy (6.3) as follows:<br />

f buc � K·C L(9C s � 1100h/s) � ( f cu) 0.5<br />

where f buc � characteristic bond strength in N/mm 2<br />

f cu � characteristic grout compressive strength in N/mm 2<br />

K � stiffness factor (see below)<br />

C L � coefficient for grout length to pile diameter ratio<br />

C s � surface condition factor<br />

h � minimum shear connector outst<strong>and</strong> in mm<br />

s � nominal shear connector spacing in mm<br />

The stiffness factor is given by<br />

K � 1 m� D t � �1<br />

g<br />

��� D t � � � p<br />

D t � s� �1<br />

(6.6)<br />

(6.7)