(a) (b) (c)<br />

Lifting rope<br />

Lifting points<br />

L 5<br />

(d) (e) (f)<br />

(g) (h)<br />

Figure 7.1 Methods of lifting reinforced concrete piles.<br />

L<br />

3<br />

L 5<br />

L 4<br />

Structural design of piles <strong>and</strong> pile groups 377<br />

characteristic strength of 40 N/mm 2 has been used with a characteristic strength for the<br />

reinforcement of 250 N/mm 2 , <strong>and</strong> 40 mm cover to the link steel.<br />

It is desirable to limit the steel stresses to 250 N/mm 2 when determining ultimate<br />

resistance moments. This will ensure that a 4 bar reinforcement arrangement complies<br />

with Table 3.30 of BS 8110: Part 1 regarding maximum spacing requirements, that is,<br />

300 mm assuming no redistribution. If a characteristic strength of 460 N/mm 2 were to be<br />

used, the maximum allowable bar spacing becomes 160 mm, thus requiring an 8 bar<br />

arrangement.<br />

However, the situation can arise in which a moment is induced in a pile due to the pile being<br />

driven just within the permitted tolerance of 1 in 75 to the vertical. In such a case the pile<br />

can be checked as a column with an axial load <strong>and</strong> moment, by use of the design charts in<br />

BS 8110: Part 3. These charts relate only to high-yield steel with a characteristic strength of<br />

460 N/mm 2 . It is therefore advisable to use high-yield steel for pile reinforcement, but to limit<br />

the characteristic strength to 250 N/mm 2 when designing for lifting from the casting bed.<br />

The charts can be used for a concrete having a higher characteristic strength but the lifting<br />

lengths will be somewhat conservative. The concrete strength is usually governed by the<br />

strength required to resist driving stresses (see Section 2.2.2), or to give durability in an<br />

aggressive environment (see Section 10.3 <strong>and</strong> Clauses 4 <strong>and</strong> 7 of EC2).<br />

The length <strong>and</strong> cross-sectional dimensions of the pile are obtained from considerations of<br />

the resistance of the soil or rock to axial or lateral loading (Chapters 4 <strong>and</strong> 6). Then for the<br />

given length <strong>and</strong> cross-section the pick-up point is selected, having regard to the type of<br />

piling plant <strong>and</strong> craneage to be employed, <strong>and</strong> the economies which may be achieved by<br />

lifting the piles from points other than at the ends or the centre. The bending moment due to<br />

L<br />

4<br />

L 2<br />

L 4<br />

L 2<br />

3L<br />

10<br />

L<br />

5