162 Resistance of piles to compressive loads<br />

Fleming <strong>and</strong> Sliwinski (4.12) reported no difference in the adhesion factor between bored<br />

piles drilled into clays in bentonite-filled holes <strong>and</strong> dry holes. In spite of this evidence it<br />

must be pointed out that if the use of a bentonite slurry to support an unlined hole in clay<br />

does not reduce the shaft friction this must mean that the rising column of concrete placed<br />

by tremie pipe beneath the slurry has the effect of sweeping the slurry completely off<br />

the wall of the borehole. It is difficult to conceive that this happens in all cases; therefore<br />

the adhesion factor � recommended for London Clay, or for other clays in Figure 4.8, should<br />

be reduced by 0.8 to allow for the use of bentonite unless a higher value can be demonstrated<br />

conclusively by loading tests.<br />

In clays other than London Clay, where there is no information from loading tests or<br />

publications, the adhesion factors shown in the curve for bored piles in glacial till<br />

(Figure 4.8) can be used as a guide to pile design. The calculated pile capacity should be<br />

confirmed by field loading tests.<br />

The procedure for checking the ULS resistance of bored piles in clay when using the EC7<br />

rules is the same as described in Section 4.2.1 for driven piles. The �b <strong>and</strong> �s partial factors<br />

in equation 4.14 are used for conventional bored piles <strong>and</strong> continuous flight auger (CFA) piles<br />

as shown in Tables 4.4 <strong>and</strong> 4.5 respectively.<br />

The greater part of the resistance of bored piles in clay is provided by shaft friction for<br />

which the component in equation 4.10 becomes . It will be noted that the value of � s<br />

�c uskA s<br />

is unity in the above tables. Hence, the engineer should give careful attention to the quality<br />

of the undisturbed sample <strong>and</strong> the laboratory testing techniques.<br />

The higher value of 1.25 for � b in bored piles in equations 4.14 <strong>and</strong> 4.15 compared with<br />

unity for driven piles reflects the influence of the fissured structure of many stiff clays, <strong>and</strong><br />

also takes into account possible inadequacies when cleaning out the base of the pile borehole<br />

before placing the concrete. The latter operation also involves the risk in soft clays of<br />

‘waisting’ or necking when placing concrete in uncased boreholes or when extracting temporary<br />

casing. Allowances for possible reductions in pile diameter due to these causes are<br />

shown in Table 4.9.<br />

When enlarged bases are provided on bored piles in a fissured clay there may be a loss of<br />

adhesion over part of the pile shaft in cases where appreciable settlements of the pile base<br />

are allowed to occur. The effect of such movements is to open a gap between the conical<br />

surface of the base <strong>and</strong> the overlying clay. The latter then slumps downwards to close the<br />

gap <strong>and</strong> this causes a ‘drag-down’ on the pile shaft. Arching prevents slumping of the full<br />

thickness of clay from the ground surface to the pile base. It is regarded as over-cautious to<br />

add the possible drag-down force to the working load on the pile, but nevertheless it may be<br />

prudent to disregard the supporting action on the pile of shaft friction over a height of two<br />

shaft diameters above the pile base, as shown in Figure 4.9.<br />

Disregarding shaft friction over a height of two shaft diameters <strong>and</strong> taking an adhesion<br />

factor of 0.3 for the friction on the remaining length may make a pile with an enlarged base<br />

an unattractive proposition in many cases when compared with one with a straight shaft.<br />

However, the enlarged-base pile is economical if the presence of a very stiff or hard stratum<br />

permits the whole of the working load to be carried in end bearing. These piles can also be<br />

advantageous where the concept of yielding or ‘ductile’ piles is adopted for the purpose of<br />

achieving load distribution between piles as discussed in Sections 5.2.1 <strong>and</strong> 5.10. Enlarged<br />

bases may also be a necessity to avoid drilling down to or through a water-bearing layer in<br />

an otherwise impervious clay.