Table 3.8 Feedwater quality, PLWTP<br />

Parameter (mg/L) Raw sewage Advanced primary<br />

treated sewage<br />

Ammonia-N 27.3 26.6<br />

BOD 5 213 97<br />

COD 463 216<br />

TOC 40 44<br />

TKN 42.9 44.8<br />

Ortho-phosphate-P 0.61 0.46<br />

Table 3.9 Design information, PLWTP<br />

Design 139<br />

Kubota USFilter Zenon Mitsubishi Rayon<br />

Screening 3.2 mm travelling 1.0 mm wedge 0.75 mm 0.75 mm<br />

b<strong>and</strong> screen wire slotted perforated perforated rotary<br />

Tank sizes (m<br />

rotary screen rotary drum<br />

screen<br />

drum screen<br />

3 )<br />

Denitrification 6.42 3.79* – –<br />

Nitrification 12.5 5.7 4.92 6.06<br />

<strong>Membrane</strong> – 0.34 0.7 0.95<br />

Recycle ratio<br />

<strong>Membrane</strong><br />

4 (303 l/min) – – –<br />

Type 510 B10 R ZW500d Sterapore SUR<br />

Configuration 100 panels/deck, 4 modules 3 modules 50 modules/<br />

double deck bank, two banks<br />

Total membrane<br />

area (m<br />

160 37 69 100<br />

2 )<br />

*Not used in trial.<br />

oxygen from fine bubble aeration than the other technologies (Table 3.10). This being<br />

said, the data for specific aeration dem<strong>and</strong> appear to demonstrate that, for this trial:<br />

(a) <strong>The</strong> Mitsubishi Rayon system had a significantly higher specific aeration<br />

dem<strong>and</strong> with respect to membrane aeration (SAD m <strong>and</strong> SAD p), reflecting the<br />

somewhat lower permeability <strong>of</strong> the membrane material.<br />

(b) <strong>The</strong>re was little difference in the figures for the total specific aeration dem<strong>and</strong><br />

(TSAD p) <strong>of</strong> all those technologies operating without denitrification under the<br />

most optimum conditions, the figures ranging from 51 to 62.<br />

<strong>The</strong> latter point is interesting in that it suggests one <strong>of</strong> two things: (a) that the air<br />

from fine bubble aeration somehow ameliorated membrane fouling, or (b) that the<br />

coarse bubble aeration contributed substantially to the DO.<br />

<strong>The</strong> permeability data also provides interesting information on system operation<br />

<strong>and</strong> maintenance. <strong>The</strong> Zenon system was the only one operated with regular (three<br />

times a week) maintenance cleans by backpulsing with chlorine (250 ppm) or citric