stainless steel cables connected with a shock-absorbing device<br />

to an aluminum box section, which is attached to the jambs,<br />

the underside of the header, <strong>and</strong> topside of the sill. The energy<br />

absorbing characteristics allow the catch systems to be attached<br />

to relatively weakly constructed walls without the need <strong>for</strong> additional<br />

costly structural rein<strong>for</strong>cement. To reduce the possibility<br />

of slicing the laminated glass, the cable may either be sheathed<br />

in a tube or an aluminum strip may be affixed to the glass directly<br />

behind the cable.<br />

2.5.2.3 Internal Partitions. Unrein<strong>for</strong>ced masonry walls provide<br />

limited protection against airblast due to explosions. When subjected<br />

to overload from air blast, brittle unrein<strong>for</strong>ced CMU walls<br />

will fail <strong>and</strong> the debris will be propelled into the interior of the<br />

structure, possibly causing severe injury or death to the occupants.<br />

This wall type has been prohibited <strong>for</strong> new construction where<br />

protection against explosive threats is required. Existing unrein<strong>for</strong>ced<br />

CMU walls may be retrofitted with a sprayed-on polymer<br />

coating to improve their air blast resistance. This innovative retrofit<br />

technique takes advantage of the toughness <strong>and</strong> resiliency<br />

of modern polymer materials to effectively de<strong>for</strong>m <strong>and</strong> dissipate<br />

the blast energy while containing the shattered wall fragments.<br />

Although the sprayed walls may shatter in a blast event, the elastomer<br />

material remains intact <strong>and</strong> contains the debris.<br />

The blast mitigation retrofit <strong>for</strong> unrein<strong>for</strong>ced CMU walls consists<br />

of an interior <strong>and</strong> optional exterior layer of polyurea applied to<br />

exterior walls <strong>and</strong> ceilings (see Figure 2-16). The polyurea provides<br />

a ductile <strong>and</strong> resilient membrane that catches <strong>and</strong> retains<br />

secondary fragmentation from the existing concrete block as it<br />

breaks apart in response to an air blast wave. These fragments, if<br />

allowed to enter the occupied space, are capable of producing serious<br />

injury or death to occupants of the structure.<br />

Structural deSign criteria<br />

2- 9