In lieu of the elastomer, an aramid (Geotextile) debris catching<br />

system may be attached to the structure by means of plates bolted<br />

through the floor <strong>and</strong> ceiling slabs (see Figure 2-17). Similar to<br />

the elastomer retrofit, the aramid layer does not strengthen the<br />

wall; instead, it restrains the debris that would otherwise be propelled<br />

into the occupied spaces.<br />

2- 0 Structural deSign criteria