exit is commonly defined as a protected path of travel to the exit<br />

discharge (NFPA 101, 2006). The stairways in a high-rise building<br />

commonly meet the definition of an exit. In general, the exit is<br />

intended to provide a continuous, unobstructed path to the exterior<br />

or to another area that is considered safe. Most codes require<br />

that exits discharge directly to the outside. Some codes, such as<br />

NFPA 101, permit up to half of the exits to discharge within the<br />

building, given that certain provisions are met.<br />

There is no universally accepted st<strong>and</strong>ard on emergency evacuation.<br />

<strong>Design</strong> considerations <strong>for</strong> high-rise buildings relative to<br />

these two options involve several aspects, including design of<br />

means of egress, the structure, <strong>and</strong> active fire protection systems<br />

(e.g., detection <strong>and</strong> alarm, suppression, <strong>and</strong> smoke management).<br />

Many local jurisdictions, through their fire department<br />

public education programs, have developed comprehensive <strong>and</strong><br />

successful evacuation planning models but, unless they are locally<br />

adopted, there is no legal m<strong>and</strong>ate to exercise the plans. Seattle,<br />

Phoenix, Houston, <strong>and</strong> Portl<strong>and</strong>, Oregon, are among the cities<br />

that have developed comprehensive programs.<br />

The NIST life safety, egress, <strong>and</strong> emergency response findings<br />

provide valuable lessons learned <strong>for</strong> future shelter evacuation<br />

design. Currently, building fire protection is based on a four-level<br />

hierarchical strategy comprising alarm <strong>and</strong> detection, suppression<br />

(sprinklers <strong>and</strong> firefighting), compartmentation, <strong>and</strong> passive protection<br />

of the structure.<br />

m Manual stations <strong>and</strong> detectors are typically used to activate<br />

fire alarms <strong>and</strong> notify building occupants <strong>and</strong> emergency<br />

services.<br />

m Sprinklers are designed to control small <strong>and</strong> medium fires<br />

<strong>and</strong> to prevent fire spread beyond the typical water supply<br />

design area of about 1,500 square feet.<br />

m Compartmentation mitigates the horizontal spread of more<br />

severe but less frequent fires <strong>and</strong> typically requires fire-rated<br />

design considerations<br />

1-4