interior room is preferable to a room with exterior walls, if it<br />

meets criteria <strong>for</strong> size, tightness, <strong>and</strong> accessibility. For a low-rise<br />

building, there is no substantial advantage in a room on the<br />

higher floors, <strong>and</strong> a location should not be selected based on<br />

height above ground level if it increases the time required to<br />

reach the shelter in an emergency.<br />

m Water <strong>and</strong> toilets. Drinking water <strong>and</strong> a toilet(s) should be<br />

available to occupants of a safe room. This may involve the use<br />

of canned/bottled water <strong>and</strong> portable toilets. Toilet fixture<br />

allowance is presented in <strong>FEMA</strong> 361.<br />

m Communications. For sheltering situations initiated by local<br />

authorities, the safe room must contain a radio with which<br />

to receive emergency instructions <strong>for</strong> the termination of<br />

sheltering. A telephone or cell phone can be used to receive<br />

emergency instructions <strong>and</strong> to communicate with emergency<br />

management agencies. Electrical power <strong>and</strong> lighting are also<br />

required.<br />

3.4 DeSiGn anD inSTaLLaTion oF a ToXiCaGenT<br />

SaFe RooM<br />

After the room or location <strong>for</strong> the safe room has been decided<br />

based on the criteria listed above, the first design decision is to determine<br />

the class of safe room. <strong>Design</strong> details <strong>for</strong> the three classes<br />

of safe rooms are presented below. A Class 3 <strong>Safe</strong> Room is the<br />

simplest in that it requires only a tight enclosure. It is presented<br />

first because the requirements of the tight enclosure are common<br />

to all three classes. The unventilated Class 2 <strong>Safe</strong> Room, which<br />

involves the simplest application of a filter unit, is presented next,<br />

<strong>and</strong> the Class 1 <strong>Safe</strong> Room, which involves a more complex application<br />

of a filter unit, is presented last.<br />

CBR ThReaT pRoTeCTion<br />

3-