Cooling<br />

Cooling<br />

Rittal Liquid Cooling Package, useful cooling output 10 kW – 40 kW<br />

Model No. SK 3301.4901) 3301.2302) 3301.420 3301.4801) Available on request.<br />

Description LCP Extend LCP Standard LCP Plus LCP Plus<br />

Rated operating voltage V, Hz 230, 50/60 230, 50/60 230, 50/60 230, 50/60<br />

W 520<br />

300 300 300<br />

300<br />

Dimensions in mm<br />

H 1910<br />

2000 2000 2000<br />

2400<br />

D 160<br />

1000 1200 1200<br />

1200<br />

Usable U 42 42 42 51<br />

Useful cooling output 12 kW Up to 20 kW Up to 30 kW Up to 40 kW<br />

Rated current 2.4 A/3.0 A 3.8 A/4.4 A 9.3 A/10.4 A<br />

Pre-fuse 6 A/6 A 10 A/10 A 16 A/16 A<br />

Cooling medium Water (for specifications see Internet)<br />

Water inlet temperature +15°C +6°C to +20°C<br />

Permissible operating pressure p. max. 6 bar 6 bar 6 bar<br />

Protection category to EN 60 529/10.91 – IP 30<br />

Duty cycle 100 %<br />

Technical specifications<br />

Electrical connection Connection cable<br />

available on request.<br />

Water connection 3 /4″ external thread 1″ external thread<br />

Weight 130 kg max. 170 kg 150 kg<br />

Colour RAL 7035<br />

Air throughput of fans 3000 m3 /h 4800 m3 /h<br />

Temperature control<br />

Additional module<br />

Fan control<br />

Electronically controlled magnetic valve<br />

and 4-way fan control<br />

Useful cooling output max. 6.6 kW – 3301.250 – –<br />

Special voltages and sizes available on request. We reserve the right to make technical modifications.<br />

Rack heights of 2200 mm are achieved with an optional add-on cover.<br />

1) Delivery times available on request.<br />

2) Also available with 115 V, Model No. 3301.210.<br />

To ensure proper use of LCP Standard and LCP Plus, the racks being<br />

cooled should be sealed against the ingress of ambient air wherever<br />

possible:<br />

Description Dimensions in mm Packs of Model No.<br />

Side panel, screw-fastened H x D 2000 x 1000 2 8100.235<br />

Glazed door W x H<br />

Sheet steel door, solid W x H<br />

Divided partitioning plate for<br />

retrospective sealing in the<br />

base area<br />

Divided roof plate<br />

for cable entry<br />

W x D<br />

W x D<br />

1) Delivery times available on request.<br />

2) Retrospective installation is not possible.<br />

600 x 2000 1 8610.6001) 800 x 2000 1 8610.8001) 600 x 2000 1 7824.2051) 800 x 2000 1 7824.2071) 600 x 1000 1 7825.300<br />

800 x 1000 1 7825.302<br />

600 x 1000 1 7826.6052) 800 x 1000 1 7826.8052) Accessories Page 131 Recooling systems From page 133 Server enclosures From page 73<br />

Other accessories:<br />

Recooling systems,<br />

see page 133.<br />

Quick-release fastener,<br />

see page 132.<br />

Base/plinth,<br />

see page 254.<br />

Service,<br />

see page 150.<br />

Water/water heat exchanger,<br />

available on request.<br />

130 Rittal IT catalogue/Cooling

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!