482.6 mm (19″)/metric installation<br />

482.6 mm (19″) installation<br />

482.6 mm (19″)/metric installation<br />

Adaptor, 3 U<br />

Depth offset 100 mm<br />

This adaptor is used to recess 482.6 mm (19″)<br />

mounting of equipment inside enclosures with 19″<br />

installation in the foremost position, such as server<br />

or electronic enclosures. In this way, sufficient<br />

space can be gained in front of the mounting<br />

equipment to integrate patch panels or switches,<br />

whilst at the same time exploiting the maximum<br />

enclosure depth.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Mounting kit, 2 U<br />

For 482.6 mm (19″) equipment<br />

Facilitates fast, simple integration of additional 2 U<br />

mounting space within an enclosure by attaching<br />

to the enclosure frame or to the existing mounting<br />

angles at the sides. The flexible slot fastening of<br />

the brackets means that the distance between the<br />

two installation brackets may be freely selected,<br />

so that other 482.6 mm (19″) attachment dimensions<br />

may be implemented.<br />

The second row of holes is used for the optional<br />

configuration of additional mounting surfaces.<br />

Material:<br />

Sheet steel, zinc-plated, passivated<br />

Supply includes:<br />

Assembly parts.<br />

Infill panel, hinged<br />

for 800 mm wide TS network enclosures<br />

To cover the side cable chamber. The infill panel<br />

is attached to the vertical enclosure frame at the<br />

front. The generous curved design will conceal<br />

even large quantities of cables, and facilitates<br />

combined use with large-scale shunting rings<br />

DK 7220.600.<br />

The infill panel has a hinged design and allows<br />

easy access to the cabling level by simply swinging<br />

it out. Locating points keep the panel in its<br />

open and closed state.<br />

With an offset 482.6 mm (19″) mounting level the<br />

panel may likewise be offset in the enclosure<br />

depth and secured to TS punched sections with<br />

mounting flange on the inner mounting level.<br />

For mounting the 482.6 mm (19″) attachment level<br />

in front-most mounting position, version with<br />

straight trim panel.<br />

Material:<br />

Sheet steel, spray-finished in RAL 7035<br />

Supply includes:<br />

Assembly parts.<br />

Packs of Model No. DK<br />

2 7246.400<br />

Packs of Model No. DK<br />

2 7246.420<br />

For<br />

installation height<br />

U<br />

Accessories:<br />

TS punched section with mounting flange,<br />

see page 299.<br />

Note:<br />

The installation of depth stays,<br />

e.g. DK 7827.600/.800 is not possible.<br />

380 Rittal IT catalogue/System accessories<br />

Packs<br />

of<br />

Trim panel<br />

curved<br />

Model No. TS<br />

Trim panel<br />

straight<br />

33 2 7827.530 –<br />

38 2 7827.532 7827.5181) 42 2 7827.534 7827.520<br />

47 2 7827.536 7827.5221) 1) Delivery times available on request.