Technical properties depending on<br />

variant:<br />

Rocker switch<br />

Illuminated, 2-pole switch. The safety bars<br />

prevent accidental contact.<br />

Master/slave<br />

2-pole electronic switching unit. The operating<br />

point may be set from 9 W to 35 W.<br />

Equipment which switches to energy-saving<br />

or stand-by mode when switched on cannot<br />

be used as the master device. In the ON<br />

state, the master device must draw 9 W, and<br />

must not draw more than 35 W in the OFF<br />

state.<br />

Overvoltage protection and interference<br />

suppression filter<br />

The connected equipment is protected from<br />

voltage peaks in the mains and spikes. The<br />

EMC interference suppression filter provides<br />

protection from high-frequency interference<br />

voltage from both directions – the<br />

mains and the connected equipment.<br />

The green ready light is extinguished in the<br />

event of disconnection or malfunctions. Connected<br />

equipment remains disconnected.<br />

DK 7240.110<br />

262<br />

232.5<br />

31.75<br />

44<br />

DK 7240.200 – DK 7240.290<br />

DK 7240.370<br />

DK 7240.200<br />

482.6<br />

452.5<br />

482.6<br />

452.5<br />

Rittal IT catalogue/System accessories<br />

720.6<br />

691.5<br />

(32.3) 97 88 88 88 57<br />

DK 7240.205<br />

482.6<br />

452.5<br />

Overvoltage protection device (SPD),<br />

type 3<br />

Maximum continuous voltage Uc: 280 V AC<br />

Rated load current IL: 16 A<br />

Maximum overvoltage protection at the<br />

mains end:<br />

LS:B16A or 16AgL/gG<br />

Protection level Up: 1.5 kV<br />

Combined surge Uco (L-N): 5 kV<br />

Combined surge Uco (L/N-PE): 6 kV<br />

Rated discharge current In (L-N): 3.0 kA<br />

Rated discharge current In (L/N-PE): 6.5 kA<br />

Arrester disconnector: Permanently disconnects<br />

SPD and equipment from the mains.<br />

Status display: Green ready light is extinguished<br />

upon disconnection.<br />

Overvoltage protection and interference<br />

suppression filter, with RJ 10 connector<br />

for connection to the CMC.<br />

With the relay message contact, undervoltage<br />

and any failures caused by overvoltage<br />

can be reported via the CMC in the network<br />

using an SNMP trap.<br />

Relay alarm output: RJ 10 jack<br />

Relay load capacity: 50 V DC, 100 mA<br />

10 A circuit-breaker<br />

Protects cables from short-circuit and overload.<br />

2-pole switching (thermal/magnetic).<br />

Tripping characteristic B.<br />

(32.3)<br />

(32.3) 273 88 57 (32.3)<br />

31.75<br />

44<br />

44<br />

44<br />

DK 7240.120<br />

DK 7240.201<br />

31.75<br />

44<br />

306.6<br />

276.5<br />

Interior installation<br />

Power supply<br />

UPS strip<br />

With red socket inserts. These indicate the<br />

items of equipment protected by a UPS.<br />

Connection cable with IEC 320 connector.<br />

Cable: H05VV-F3G1.0/rated current: 10 A<br />

2 circuits<br />

Two circuits with two separate connection<br />

cables, 2.5 m.<br />

RCCB<br />

For personal protection. With residualcurrent<br />

circuit-breaker I∆n 30 mA to<br />

DIN VDE 0664 part 1/85.<br />

RCCB and line protection<br />

A combination of personal, overload and<br />

short-circuit protection. With residual-current<br />

circuit-breaker I∆n 30 mA to DIN VDE 0664<br />

part 1/85 and residual-current circuitbreaker<br />

to DIN VDE 0641/A 4/11.88 16 A/<br />

250 V~.<br />

Version B/F (Belgium/France)<br />

With 7 or 12 sockets to CEE 7-V UTE,<br />

with child-proof system.<br />

IEC connector<br />

With connection sockets to IEC 320,<br />

connection cable, 2 metres or IEC 320 input<br />

in the connector panel.<br />

Cable: H05VV-F3G1.0/rated current: 10 A<br />

482.6<br />

452.5<br />

31.75<br />

44<br />

(32.3) 141 110 110 57 (32.3)<br />

DK 7240.510<br />

482.6<br />

452.5<br />

(32.3) 119 44 44 44 44 44 44 35 (32.3)<br />