Engineering and consultancy<br />

Engineering and consultancy<br />

Server configuration/integration<br />

Configuration of a server<br />

rack<br />

The following points need to be considered<br />

when selecting a suitable rack for the integration<br />

of servers and other active components,<br />

in order to guarantee an optimum<br />

solution for the individual customer-specific<br />

application.<br />

Rack configuration<br />

Rittal offers pre-configured server racks<br />

which are tailored especially to the demands<br />

of server integration:<br />

● Vented doors for optimum server ventilation<br />

● Roof plate for cable entry<br />

● Quick-release side panels (optional in<br />

some cases)<br />

● 19″ attachment levels<br />

● Levelling feet<br />

● Castors (optional in some cases)<br />

● Stabilisers (optional in some cases)<br />

Rittal also offers a comprehensive range of<br />

accessories which enable each customer to<br />

configure an individual server rack.<br />

Rack dimensions<br />

The server depth is a particularly important<br />

criterion for rack selection. The depths<br />

900 mm, 1000 mm and 1200 mm have<br />

proven particularly suitable for the installation<br />

of most models. These depths not only<br />

accommodate the server itself, but also provide<br />

the necessary space for cable management<br />

to the rear of the rack.<br />

The rack dimensions (height x width x<br />

depth) must also be matched to the available<br />

floor space.<br />

Server integration accessories<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

Universal server installation kit, 482.6 mm (19″)<br />

● for distance between 482.6 mm (19″) levels<br />

of 750 mm<br />

Various mounting adaptors for accommodating<br />

customer-specific installation kits<br />

Depth-variable slide rail, 1 U<br />

● for distance between 482.6 mm (19″) levels<br />

of 390 – 930 mm<br />

Telescopic slides (for full withdrawal)<br />

Depth-variable mounting kit<br />

for 482.6 mm (19″) component shelves<br />

● for distance between 482.6 mm (19″) levels<br />

of 390 – 1000 mm<br />

482.6 mm (19″) component shelves<br />

● for static installation<br />

● for full extension<br />

(additionally with telescopic slide)<br />

Manufacturer-specific installation kit<br />

19″ mounting level<br />

Servers are generally installed in the rack on<br />

the front and rear 482.6 mm (19″) levels,<br />

whereby L-shaped 482.6 mm (19″) mounting<br />

angles or 482.6 mm (19″) mounting<br />

frames are preferable for attachment purposes.<br />

Cranked mounting angles are not<br />

generally suitable for server installation.<br />

The integrated U markings on the mounting<br />

angles serve to facilitate installation within<br />

the 482.6 mm (19″) level.<br />

Cable management<br />

Cable entry into a rack can be from below,<br />

from above or from the sides. It is furthermore<br />

important to bundle the cables in the<br />

rack itself and to route them in such a way<br />

that any heat build-up and the resultant<br />

server failures can be reliably avoided. To<br />

this end, Rittal offers an extensive range of<br />

cable management products,<br />

including:<br />

● Roof and gland plates with cable routing<br />

options<br />

● Protected cable routing via cable ducts<br />

in co-location racks<br />

● Partitions with openings for cable entry<br />

● Cable shunting rings, clamp rails, cable<br />

management ducts etc.<br />

Climate control<br />

In order to avoid heat accumulation inside<br />

the server rack, heat dissipation must be<br />

ensured, and can be additionally assisted:<br />

● Passive enclosure ventilation with slotted<br />

front and rear doors to the server rack.<br />

● Active enclosure ventilation – the Rittal fan<br />

cross member provides for selective ventilation<br />

of critical hot-spots in the server<br />

rack. It is mounted directly on the slotted<br />

server door.<br />

● Climate management for the server rack<br />

via CMC-TC to monitor temperature limit<br />

values and to control fan and cooling units<br />

to maintain as constant a temperature as<br />

possible.<br />

● High Performance Cooling Racks (HPC)<br />

in conjunction with heavy-duty heat<br />

exchangers for climate management in<br />

the high-performance range.<br />

Server integration<br />

Most standard server models are supplied<br />

with manufacturer-specific installation kits,<br />

which are then generally attached to the<br />

482.6 mm (19″) mounting angles at the front<br />

and rear of the rack. Not all installation kits,<br />

however, are depth-variable, and some<br />

manufacturers offer housings which cannot<br />

be mounted on the front and rear 482.6 mm<br />

(19″) angles. The following Rittal products,<br />

furthermore, can be used to enable mixed<br />

configurations of different types in one rack:<br />

● Universal server installation kit with mounting<br />

adaptor for different servers and 482.6<br />

mm (19″) distance between levels<br />

● Depth-variable slide rails<br />

● Depth-variable installation kits for<br />

482.6 mm (19″) component shelves<br />

● 19″ component shelves, 50 kg, 80 kg and<br />

100 kg load capacity<br />

412 Rittal IT catalogue/Engineering/Consultancy<br />

1<br />

6<br />

2<br />

7<br />

3<br />

4<br />

5