<strong>GE</strong> Oil <strong>and</strong> Gas<br />

<strong>SVI</strong> <strong>II</strong> <strong>AP</strong> Instruction Manual<br />

Table 26<br />

Tight Shutoff Parameters for High Pressure Liquid Letdown Trim<br />

<strong>Masoneilan</strong> Valve<br />

Type<br />

Valve Trim Type Set Tight Shutoff Positioner<br />

Characteristics<br />

Lincoln Log Any 15% Linear<br />

41000 VRT Type S Partial Stack 6% Linear<br />

41000 VRT Type S Full Stack 3.5% Linear<br />

41000 VRT Type C Cage 6% Linear<br />

28000 Varilog 5% Linear<br />

Any Class V Shutoff 2% Linear<br />

Using ValVue Diagnostics<br />

<strong>SVI</strong> <strong>II</strong> <strong>AP</strong> advanced features are simple to use with ValVue software. The following<br />

examples illustrate some uses.<br />

Continuous Diagnostics<br />

<strong>SVI</strong> <strong>II</strong> <strong>AP</strong> continuously gathers critical information that can be used to predict<br />

maintenance intervals for control valves. These are:<br />

Total Travel<br />

Number of cycles<br />

Time open<br />

Time closed<br />

Time near closed<br />

Monitoring a Valve Bellows Seal<br />

The <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> automatically stores the accumulated valve stroke reversals, as Number of<br />

cycles. ValVue can be used to periodically retrieve the values <strong>and</strong> to track the remaining<br />

life of a bellows seal or packing. Total travel can also be used to estimate the remaining<br />

life of packings <strong>and</strong> seals.<br />

Critical Service, Cavitation Control Trim<br />

The time near closed, of a valve with severe service when near the seat, can be<br />

monitored by ValVue <strong>and</strong> saved to permanent files to monitor <strong>and</strong> predict maintenance<br />

needs. You can use ValVue to specify the criterion for time-spent-near-closed (a valve<br />

position such as 4%, for example). See also Tight shutoff- Application to High Pressure<br />