Hazardous Area<br />
High Flow<br />
Hot Swappable<br />
I⁄P Converter<br />
ISA<br />
Multidrop<br />
Multiplexer<br />
NAMUR<br />
Neodymium Iron<br />
Boron<br />
The area of the plant where explosion hazards are present,<br />
hazards such as propane gas in a refinery, or dust in a flour mill.<br />
The <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> High Flow Positioner improves the dynamic performance<br />
of medium to large volume actuators without the need<br />
of a volume booster.<br />
The <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> in combination with ValVue enables a very brief<br />
Mean Time To Repair by the following process: Upload all configuration<br />
information from installed positioner to ValVue, then<br />
replace the positioner <strong>and</strong> download the configuration file. Run<br />
STOPS, <strong>and</strong> autoTUNE, <strong>and</strong> the repair is complete.<br />
The current to pressure converting device. The <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> sends<br />
an analog current signal to the I⁄P which produces a controlled<br />
pressure to the pneumatic amplifying relay.<br />
The Instrument Society of America. ISA develops <strong>and</strong> publishes<br />
international st<strong>and</strong>ards for use in process control. See<br />
www.isi.org.<br />
A variation of the HART Communications Protocol that allows<br />
many smart field devices to draw power from <strong>and</strong> to communicate<br />
over a single pair of wires. Though most suited to multiple<br />
measurement devices, it can be used with <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> to permit<br />
digital communication of setpoint as well as configuration data,<br />
to multiple positioners or a combination of positioners <strong>and</strong> measurement<br />
transmitters. Such communication may not be fast<br />
enough for flow control.<br />
Several instrument suppliers offer equipment that can be connected<br />
to multiple cables to monitor <strong>and</strong> communicate with the<br />
attached positioners <strong>and</strong> transmitters using the HART protocol.<br />
Often the multiplexer is used with a DCS that does not support<br />
HART.<br />
NAMUR is a European user association of process control<br />
technology in chemical <strong>and</strong> pharmaceutical industries. “Recommendations<br />
<strong>and</strong> Worksheets are experience reports <strong>and</strong> working<br />
documents prepared by NAMUR for its members among<br />
process control users for facultative utilization”. NAMUR issued<br />
a recommended accessory mounting for control valves (NE 14<br />
Anschluß von Schwenkantrieben an Armaturen 06.08.96)<br />
which describes a method for mounting a positioner on an actuator.<br />
See at www.namur.de.<br />
A magnet alloy which provides the highest energy magnetism<br />
available in a permanent magnet.<br />