Glossary<br />

F<br />

Accuracy<br />

Actuator<br />

Type<br />

Algorithm<br />

ATC Air to<br />

Close<br />

ATO Air to<br />

Open<br />

CALIBrate<br />

In a control valve the position is measured between mechanical motion limits<br />

in the valve. These limits can include position variations due to actuator <strong>and</strong><br />

valve rigidity. therefore, accuracy is referenced to positions within normal<br />

travel of the valve independent of rigidity effects at the mechanical limits.<br />

Accuracy is the greatest deviation from the expected position within the normal<br />

travel, expressed as percent of normal travel.<br />

An actuator is a device that transforms an input signal (mainly an electrical<br />

signal) into motion. A HART compliant actuator receives a 4 - 20 mA control<br />

current signal <strong>and</strong> causes an actuation function. There are many types of<br />

HART actuators; a positioner is type of actuator. A device of type Actuator<br />

can not be connected to a circuit intended for a device of type Transmitter.<br />

An algorithm is a procedure or formula for solving a problem. There are several<br />

algorithms entailed in <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> operation. The <strong>SVI</strong> <strong>II</strong> <strong>AP</strong> has a position<br />

control algorithm that is a modified PID. Other algorithms embedded in <strong>SVI</strong> <strong>II</strong><br />

<strong>AP</strong> include the STOPS method for calibrating stroke, <strong>and</strong> the autoTUNE<br />

method for establishing the best parameters for the PID algorithm.<br />

The combination of a single acting actuator <strong>and</strong> the control valve where the<br />

valve is closed when air pressure is applied to the actuator.<br />

The combination of a single acting actuator <strong>and</strong> the control valve where the<br />

valve is open when air pressure is applied to the actuator.<br />

A mode of the positioner in which you can change the calibration of stroke,<br />

input signal, <strong>and</strong> tuning parameters.<br />